NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 173 pages

Chain of Custody: NYC DEP sample handling

Machine-extracted title · confidence 60%

Chain-of-custody form for environmental samples, lab information.

NYC-WTC_000418162–000418334
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

!!:;>.-s.'Ci-.-.vvv-.-cr.- .-.i: Tii T.r.— -nf.j'..

Z z o CA RICH COIMSULTAMTB, INC. o i 1^ co

■D o c o mixture and total sample volume are then used to quantify the PCS concentrations in the air CT o o' oo samples. "0 o o 03

O All Lead Air Sampling was conducted in accordance with the sampling, sample preparation, and o o c analysis requirements of NiOSH Method 7300. As required, all personal sampling pumps were 3 Q calibrated to a flow rate of 2 liters per minute. The pumps were run to collect a total sample 3

volume of greater than 360 liters of air. Each air sample was collected on a 37-mitlimeter (mm) cellulose ester membrane filter, with a 0.8-micron pore size, mounted in 37-mm filter cassette and sealed with plastic plugs and a cellulose band. Alter drawing the sample, the samples were then shipped to Galson Laboratories for analysis. Analysis consisted of adding ashing acid to the filter and developing a mixture. This mixture is then analyzed by inductively-coupled plasma- atomic emission spectrometry to determine the micrograms of lead in the mixture. The micrograms in the mixture and total sample volume are used to calculate the lead concentration in the air.

All Asbestos Air Sampling was conducted in accordance with the sampling, sample preparation, I and analysis requirements of EPA Level II. EPA Level II requires the calibration of all ambient t-u. sampling pumps to a maximum flowrate of 12 liters per minute. Sampling pumps were run to collect a total sample volume of greater than 1200 liters of air. Collection of the asbestos air I.™ samples was done on 25-'mm mixed cellulose ester filters, with a 0.45-mtcron pore size, mounted p in 25-mm filter cassettes sealed with plastic plugs and cellulose bands. After sampling, the samples were shipped to EMSL Laboratories for analysis. Analysis consisted of cutting a piece of the filter and analyzing by utilizing a Transmission Electron Microscopy to determine the

F number of asbestos structures present in the sample. The number of the asbestos structures and total sample volume are used to estimate the total asbestos structures in the air.

ANALYTICAL. RESULTS

L The levels reported for the tested contaminants that were detected were ail below the American Society of Heating,'Refrigeration, and Air-conditioning Engineers (ASHRAE) recommended indoor air quality levels. If the sampling results were less than the laboratory’s limits of detection, we considered that specific contaminant to not be detected in the air at that time. The analytical sampling results are summarized in Table 1, and only those contaminants detected above the laboratory's limit of defection are presented.

5 10256 CITY_21MC100_011970756

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418170Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →