•• ........ -.tv- '' J..,.. ■ "T t rwjwiti: rjn z«hJ: Jiisecraiaw h-trswi siSKsnst't ±J,iseti.-. t

z z o CA RICH CONSUUTANTS, IMC. o s co

'2 I o o Typically, for indoor air quality in commercial office buildings, the Occupational Safety and Health ■D c CT 4^ o' Administration's (OSHA) permissible exposure limits (PELs) divided by a safety factor of 10 are "0 OO o applied. Based upon this guidance, and in reviewing comparisons with the ambient outdoor 03

ground and roofiop concentration levels, we can conclude that the indoor air quality in the tested O o o c building spaces was found to be within acceptable parameters - as defined by ASHRAE 3 L guidelines for acceptable indoor air quality. Q 3

L The asbestos air sample results were compared to the Environmental Protection Agency’s (ERA) Asbestos Hazard Emergency Response Act (AHERA) regulation of 70 structures per square millimeter (s/mm^). All of the indoor and outdoor asbestos samples that were taken during this Survey were found to be far below this level.

CONCLUSION

Given the results of this air qualify sampling survey and the reiatively comprehensive suite of 1 tested parameters, the air quality represented at each of the tested sites was relatively good and did not contain elevated contaminant levels, when compared to EPA’s prevailing AH ERA and OSHA air quality guidelines. They are also below the ASHRAE indoor air quality guidelines.

Although a few select volatile organic compounds and an occasional detection of carbon monoxide was noted in the air at the tested Buildings, these levels are not significant and would not qualify as "contamination” or necessarily require any further response at this time given I applicable regulatory guidelines.

This Survey was performed diligentiy in consideration of the accepted practices of the environmental consulting profession. The undersigned cannot be held responsible for innocent or intentional misrepresentations or inaccurate statements, or limitations to work scope, schedule, claims, parameter source terms, or building occupation or activity, and/or information fjrnished to CA RICH that may or may not have influenced or impacted the technical approach and air quafity testing results reported herein. However, we do acknowledge that to the best of our belief, the information we have supplied Is true, complete and correct, and that facts or figures that may have an adverse effect upon the validity of the findings and conclusions developed from this Survey have not purposely been omitted.

L. 6

10257 CITY_21MC100_011970757

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418171Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →