Z z s CA RICH CONSULTANTS, INC. o co

'2 L o o were collected on a 37'millimeter (mm) polyvinyl chloride (PVC) filters, each with a 5-micron pore “0 c CT 4^ o' OO size, mounted in 37-mm filter cassette sealed with plastic plugs and a cellulose band. Each filter "0 o r” O> CD i was weighed at the laboratory prior to mounting and sampling. After sampling the samples were shipped to Galson Laboratories for analysis. The testing consisted of weighing the Alter again o o o c and reporting the difference in the results. The difference in weight and total sample volume 3 o were used to quantify the total nuisance dust concentrations in the air samples. 3

( All Mercury Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of NIOSH Method 6009, Method 6009 requires the calibration of all personal sampling pumps to a flow rate of 0,2 liters per minute. The sampling pumps were operated until a total sample volume of greater than 50 liters of air was collected. Each of the various air samples were collected on a 37-mm cellulose ester membrane filter mounted in a filter cassette followed by a sorbent tube containing 200 mg of Hopcalite held in place by glass wool plugs. PVC tubing was utilized to connect the entire sample train from the cassette at one end to the personal pump at the other end. Upon completion of the sampling, plastic caps were placed on both ends of each filter cassette and sorberrt tube. The samples were then shipped to Galson t Laboratories for chemical analyses. The testing consisted of adding nitric and hydrochloric acids to the Alter and sorbent bed to develop a mixture. This mixture is then analyzed by atomic absorption spectrophotometery to determine the micrograms of mercury tn the mixture. The E resulting micrograms in the mixture and total sample volume are then used to quantify the mercury concentrations in the air samples.

AH Pofychlorinated Biphenyl (PCB) Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of NIOSH Method 5503, As required, each sampling pump was calibrated to a flow rate of 0.2 liters per minute. The pumps were run to collect a total sample volume of greater than 48 liters of air. Each air sample was collected on a 13-mm glass fiber filter in Swinnex cassette followed by a glass tube containing two sections of 30/48 mesh deactivated Florisil. The front section of Florisil is preceded by glass wool and 100 milligram (mg) of urethane foam and the backup section contains 50mg, urethane foam. PVC tubing was utilized to connect the entire sample train from the cassette at one end to the persona! pump at the other end. When sampling was completed, the glass fiber filters were removed from the cassettes and transferred into 7-milIiliter (ml) glass vials. Plastic caps were placed on both ends of each Florisil tube. The samples were then labeled and shipped to Gatson Laboratories for analyses. The chemical analysis in the lab consisted of adding hexane and the Florisil bed to

1“ the glass vial with the filter. This mixture is then injected into a gas chromatograph with electron capture detection, to determine the micrograms of PCB tn the mixture. The micrograms in the !..

4 10255 CITY_21MC100_011970755

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418169Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →