NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 173 pages

Chain of Custody: NYC DEP sample handling

Machine-extracted title · confidence 60%

Chain-of-custody form for environmental samples, lab information.

NYC-WTC_000418162–000418334
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Hwy -J

Z z ■<

o CA RICH COIMSULTAMTS, IIMC. o i o co

■0 I c o SAMPLING PROCEDURES and METHODOLOGIES CT o o o' ■0 00 o 3. C3> Al! of the Volatiie Organic Compounds (VOCs) Air Sampling was conducted in accordance with 00 the sampling, sample preparation, and analysis requirements of EPA Compendium Method TO- o o o c 15. The stainless steel canisters required by Method TO-15 were specially calibrated and 3 CD prepared at Gaison Laboratories to collect 0.4 liters of air. At the site, the steel canister was connected to a quick grab regulator by sliding back the collar on the regulator and connecting .it to the sampler tip of the steel canister. The completion of sampling was determined once the regulator read zero. The collar was slid back again to disconnect the regulator from the canister and the stainless steel containers were plugged and shipped to Gaison Laboratories for chemical analysis. The laboratory analysis consisted of extracting the collected air, and injecting it into a Gas Chromatographic/Mass Spectrometric System (GC/MS) to determine the micrograms of the various VOCs in the air. The micrograms of each VOC in the air and total sample volume are then used to estimate each of the defected VOC concentrations in the air samples.

All of the Polynuclear Aromatic Hydrocarbons (PAHs) Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of the National institute for Occupational Safety & Health (NIOSH) Method 5506. As required, all of the pumps were calibrated to a flow rate of 2 iiters per minute. The sampling pumps were run to collect a total sample volume of greater than 360 titers of air. The air samples were collected on a 37-mm PTFE membrane filter, with a 1-mIcron pore size, mounted with a cellulose spacer ring in a 37- mm filter cassette followed by a sorbent tube containing XAD-2 resin. PVC tubing was utilized to connect the entire sample train from the cassette at one end to the persona! pump at the other end. When sampling was completed the PTFE filter was removed from the cassette and transferred into a culture tube and sealed with aluminum foil. Plastic caps were placed on both ends of each XAD-2 resin sorbent tube and then wrapped with aluminum foil. The samples were then placed in ice-filled coolers and shipped via overnight courier to Gaison Laboratories for chemical analyses. The laboratory analyses consisted of extracting PAHs from the filter and desorbing PAHs from the sorbent with acetonitrile, creating a solution. This solution is then injected into a High Performance Liquid Chromatograph (HPLC) to determine the micrograms of the various PAHs in the niixture. The micrograms of each PAH in the solution and total sample volume are used to calculate each PAH concentration in the air sample.

L... AN of the Nuisance Dust Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of NIOSH Method 0500. As required, al! of the persona! sampling pumps were calibrated to a flow rate of 2 iiters per minute. The pumps were operated unti! a total sample volume of greater than 133 liters of air was coliected. Each of the air samples

3 10254 CITY_21MC1OO_O1197O754

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418168Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →