NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 38/45 JOHN STREET; Block: 78 Lot: 28 BIN: 1001199 1-5 Dutch Street
Document / 173 pages

Chain of custody form for indoor air quality survey at

Machine-extracted title · confidence 95%

Documentation tracking the collection and handling of samples during an air quality survey at the specified building.

NYC-WTC_000108401–000108573

Folder label: “45 JOHN STREET; Block: 78 Lot: 28 BIN: 1001199 1-5 Dutch Street

Page image
Scanned page image, NYC-WTC_000108406
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I CA RICH CONSULTANTS, INC.

I I All of the Volatile Organic Compounds (VOCs) Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of EPA Compendium Method TO- 15. The stainless steel canisters required by Method TO-15 were specially calibrated and I prepared at Galson Laboratories to collect 0.4 liters of air. At the site, the steel canister was connected to a quick grab regulator by sliding back the collar on the regulator and connecting it to I the sampler tip of the steel canister. The completion of sampling was determined once the regulator read zero. The collar was slid back again to disconnect the regulator from the canister

I and the stainless steel containers were plugged and shipped to Galson Laboratories for chemical analysis. The laboratory analysis consisted of extracting the collected air, and injecting it into a Gas Chromatographic/Mass Spectrometric System (GC/MS) to determine the micrograms of the I various VOCs in the air. The micrograms of each VOC in the air and total sample volume are then used to estimate each of the detected VOC concentrations in the air samples.

I All of the Polynuclear Aromatic Hydrocarbons (PAHs) Air Sampling was conducted in accordance

I with the sampling, sample preparation, and analysis requirements of the National Institute for Occupational Safety & Health (NIOSH) Method 5506. As required, all of the pumps were calibrated to a flow rate of 2 liters per minute. The sampling pumps were run to collect a total fl sample volume of greater than 360 liters of air. The air samples were collected on a 37-mm PTFE membrane filter, with a 1-micron pore size, mounted with a cellulose spacer ring in a 37-

I mm filter cassette followed by a sorbent tube containing XAD-2 resin. PVC tubing was utilized to connect the entire sample train from the cassette at one end to the personal pump at the other end. When sampling was completed the PTFE filter was removed from the cassette and transferred into a culture tube and sealed with aluminum foil. Plastic caps were placed on both ends of each XAD-2 resin sorbent tube and then wrapped with aluminum foil. The samples were I then placed in ice-filled coolers and shipped via overnight courier to Galson Laboratories for chemical analyses. The laboratory analyses consisted of extracting PAHs from the filter and desorbing PAHs from the sorbent with acetonitrile, creating a solution. This solution is then injected into a High Performance Liquid Chromatograph (HPLC) to determine the micrograms of the various PAHs in the mixture. The micrograms of each PAH in the solution and total sample volume are used to calculate each PAH concentration in the air sample.

All of the Nuisance Dust Air Sampling was conducted in accordance with the sampling, sample preparation, and analysis requirements of NIOSH Method 0500. As required, all of the personal

I sampling pumps were calibrated to a flow rate of 2 liters per minute. The pumps were operated until a total sample volume of greater than 133 liters of air was collected. Each of the air samples

3 I NYC-WTC 000108406

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000108406Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000120991 · Box DEP Box 48

Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.

Similar indexed content

Compare copies and versions →