NYC 9/11 Public Portal Document
ATSDRIndoorAirSamDles
Questions regarding the cleaning status of apartments sampled for indoor air and dust
by the ATSDR in cooperation with the New York City Department of Health:
The testing results to date address findings of asbestos in the air and dust. When fibers
in the air are detected using Phase Contrast Microscopy (PCM), they are then analyzed
using Transmission Electron Microscopy (TEM) to determine whether or not these fibers
are asbestos fibers. Non-asbestos fibers are still being analyzed to determine their
composition. Dust samples are analyzed using Polarized Light Microscopy (PLM) and
when fibers are detected these are also analyzed by TEM to determine whether or not
these fibers are asbestos. There has been fibrous glass detected in some of the dust,
and other elements are still being analyzed.
1. How many residences were cleaned?
Fifty of 59 residences were cieaned.
2. Who cleaned them?
Thirty of these 50 were cleaned by professionals and most of the rest were
cleaned by residents.
3. How many of the not-cleaned residences had detectable levels of
non-asbestos fibers in the air?
Four of the 9 not-cleaned residences had detectable levels of non-asbestos
fibers in the air. NONE had asbestos detected in the air.
4. How many of the cleaned residences had detectable levels of non-asbestos
fibers in the air?
Twenty-four of the 50 cleaned residences had detectable levels of non-
asbestos fibers in the air. NONE had asbestos detected in the air.
5. How many of the not-cleaned residences had detectable levels of asbestos
fibers in dust?
Three of the 9 not-cleaned residences had detectable levels of asbestos in
dust by PLM or TEM testing methods. NONE of these three met the
Department of Environmental Protection (DEP) requirement for remediation
of visible dust and greater than 1% asbestos in that dust.
6. How many of the cleaned residences had detectable levels of asbestos
fibers in dust?
Seven of the 48 cleaned residences had detectable levels of asbestos in
dust by PLM or TEM. Two residences had no dust results which is why the
number of residences differs from the air results. NONE of these seven met
the DEP requirement for remediation of visible dust and greater than 1%
asbestos in that dust.