NYC 9/11 Public Portal Document
Summary ofAsbestos Sampling Results Page 2 of 3 Address: 301 East bl"" Street Date sampled: December 8, 2001
Results of Phase Contrast Microscopy (PCM) testing of air at 301 East 61st Street, Dec. 8, 2001 Area Sampled Residence
Sample Numbers A-R2-33
Concentration of fibers at 301 East 6P' St (f7cc)* <0.001
Concentration of fibers in air at all background <0.001 to 0.003 locations (f/cc)
NYC Re-occupancy Standard (f/cc)** 0.01 * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)
ASBESTOS DUST TEST RESULTS In general, the dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.
No asbestos fibers were found in the dust sample from the residence by the PLM laboratory method. TEM analysis also did not detect any asbestos in the indoor dust.
Fibrous materials in dust found by Polarized Light Microscopy (PLM) Analysis: PLM identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst will count the fibers present to give an estimate of fiber content.
CITY_21MC100_004204864
NYC-WTC_000275433
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000353959
Asbestos air/dust sampling results collected in a residential building; PCM analysis referenced.
6 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275375
Summary of asbestos and material analyses from air and dust samples at a building site, December 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208394
Summary report of asbestos air and dust sample results collected at a private residence and common areas on December 8, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275429
TEM and PLM results for dust at 161 East 88th Street.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353897
Summary of asbestos air and dust sampling results in a NYC building.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353750
Continuation of asbestos sampling results for 36 N. [name].
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275422
Summary of asbestos air testing results for 100 [name], including multiple locations and dust sampling.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353746
Continuation of asbestos sampling results for 36 N. [name].
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353738
November 27, 2001 asbestos air and dust sampling at a 36 N. [name] address.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242879
Four locations tested; air and settled dust samples analyzed for asbestos and related fibers.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353742
Indoor/outdoor asbestos sampling results for 36 N. [name] building.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301533
Page 1 of 4: four locations sampled; describes air and dust sampling methods and asbestos testing.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000353959
Asbestos air/dust sampling results collected in a residential building; PCM analysis referenced.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275375
Summary of asbestos and material analyses from air and dust samples at a building site, December 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208394
Summary report of asbestos air and dust sample results collected at a private residence and common areas on December 8, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186129
Summary report of asbestos air and dust sampling results from three locations at 161 East Street on December 8, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275429
TEM and PLM results for dust at 161 East 88th Street.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242879
Four locations tested; air and settled dust samples analyzed for asbestos and related fibers.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000353959
Asbestos air/dust sampling results collected in a residential building; PCM analysis referenced.
Similar indexed content
NYC-WTC_000275375
Summary of asbestos and material analyses from air and dust samples at a building site, December 2001.
Similar indexed content
NYC-WTC_000208394
Summary report of asbestos air and dust sample results collected at a private residence and common areas on December 8, 2001.
Similar indexed content
NYC-WTC_000275429
TEM and PLM results for dust at 161 East 88th Street.
Similar indexed content
NYC-WTC_000353897
Summary of asbestos air and dust sampling results in a NYC building.
Similar indexed content