Summary ofAsbestos Sampling Results Page 2 of 3 Address: 301 East bj"" Street Date sampled: December 8, 2001

Results of Phase Contrast Microscopy (PCM) testing of air at 301 East 61st Street, Dec. 8, 2001 Area Sampled Residence

Sample Numbers A-R2-33

Concentration of fibers at 301 East 61“ St (Ecc)* <0.001

Concentration of fibers in air at all background <0.001 to 0.003 locations (f/cc)

NYC Re-occupancy Standard (f/cc)** 0.01 * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled tlirough the filter measured in cubic centimeters. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

ASBESTOS DUST TEST RESULTS

In general, the dust and debris samples were examined by two different laboratory methods for asbestos fibers. Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

No asbestos fibers were found in the dust sample from the residence by the PLM laboratory method. TEM analysis also did not detect any asbestos in the indoor dust.

Fibrous materials in dust found by Polarized Light Microscopy (PLM) Analysis: PLM identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst will count the fibers present to give an estimate of fiber content.

CITY_21MC100_010212871

NYC-WTC_000353960

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353960Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →