Page ] of 3

Summary of Asbestos Sampling Results 161 East 88'" Street, New York, N.Y. Date sampled: December 8, 2001

Three locations were sampled at your building: inside one private residence, an indoor common area (e.g., a lobby or hallway), and a nearby outdoor area (see tables below for sampling results). One air sample was collected in the common and outdoor locations and two samples were collected from the residence. One settled dust sample was collected at each of the two indoor locations.

Air samples were collected using vacuum pumps to draw air past a filter that was suspended at the height of a person’s breathing level. Indoor dust and debris samples were collected on a filter by vacuuming surfaces. Outdoor dust samples were collected only when there was visible dust and debris to obtain bulk material. The collected material was weighed, viewed under a microscope, and/or chemically processed to determine the types and quantities of substances present. The materials are being analyzed for fibers such as asbestos, fiberglass, synthetics (e.g. man-made materials such as nylon and polyester), cellulose (e.g. cotton, paper), silica, and for other minerals and small particles.

ASBESTOS AIR TEST RESULTS The air samples tested from directly outside, in the lobby of your building, and in the apartment were taken during normal daily activity. All air samples were examined in a laboratory for fibers using the Phase Contrast Microscopy (PCM) method.

No fibers were detected in the air sample taken outdoors. One of the two samples taken in the residence did have 0.001 fibers per cubic centimeter of air (f7cc) when analyzed by PCM. The sample taken in the lobby had 0.002 f/cc. These concentrations from your building are well below the standard set for indoor air quality and therefore no follow-up action is needed.

Airborne fibers as determined by Phased Contrast Microscopy (PCM): An air sample is collected by pulling air through a filter. The filter catches fibers and is sent to a laboratory to determine what types of fibers were in the air. Phase contrast microscopy identifies fibers based on size and shape, but not the specific type of fiber. Therefore, the fibers seen by PCM include asbestos fibers as well as other fibers, such as textiles, fiberglass, cellulose, which might be present in your home.

The PCM analysis assumes that all fibers present were asbestos. Therefore, less hazardous fibers that may have been present, such as textiles or fiberglass, are counted along with the asbestos fibers, and the total fiber count is then compared to the asbestos standard (the New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work). If the PCM results from the lower Manhattan buildings were above the highest level found in the comparison buildings, additional analysis was performed to determine whether any of the fibers were asbestos.

CITY_21MC100_010212845

NYC-WTC_000208394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →