NYC 9/11 Public Portal Document
02/20/2002 09:34 FAX IM 074
Pie 1 of3
Summary of Asbestos Sampliig Results
100 John Street, New York,NY.10038
Date sampled: Dec 3, 2001
Four locations were sampled at your building: inside two
and a nearby outdoor area (see tables below for sampling privateiresidences, an indoor hallway,
results). One air and one settled dust
and debris sample was collected at each of the four
locations.
Air samples were collected using vacuum pumps to draw air
past a filter that was suspended at
the height of a person's breathing level. Outdoor dust and
debris samples were collected by
placing visible material in a container. Indoor dust and debris samples
were collected on a filter
by vacuuming surfaces. The collected material was weighed, viewed
under a microscope, and/or
chemically processed to determine the types and quantities of
are being analyzed for fibers such as asbestos, fiberglass,
substances present. The materials
synthetics (e.g. man-made materials such
as nylon and polyester), cellulose (e.g. cotton, paper), silica, and
for other minerals and small
particles.
ASBESTOS AIR TEST RESULTS
The air samples tested from taken during normal daily activity an
were examined in a laboratory
for fibers using the Phase Contrast Microscopy (PCM) method.
Results of all of the air samples
taken from your building were below the standard set for indoor stir
quality - 0.01 fibers
centimeter ('cc). All of the air sampled in your building was found to contain less than per cubic
of asbestos. This is similar to the air results from buildings located 0.001 f'cc
above 59th Street, which are
not expected to have been impacted by WTC materials. In the homes
above 59th Street, levels of
fibers found in the air ranged from less than 0.001 flee to 0.003 f/cc.
Airborne fibers as determined by PCM analysis: An air sample is
collected by pulling air
through a filter. The filter catches fibers and is sent to a laboratory to
determine
fibers in the air. Phase contrast microscopy identifies fibers based on size and the number of
specific type of fiber. Therefore, the fibers seen by PCM include asbestos fibers shape, but not the
fibers, such as textiles, fiberglass, and cellulose, which might be as well as other
present in your home. The PCM
analysis assumes that all fibers present were asbestos. Therefore, less
have been present, such as textiles or fiberglass, are counted along withhazardous fibers that may
the
the total fiber count is then compared to the asbestos standard. If the resultsasbestos fibers, and
f/cc using the PCM methodology, additional analysis was performed were above 0.003
to determine whether any of
the fibers were asbestos. In this building, additional analysis was not
warranted since the air
sampling results were not greater than 0.003 t'cc.
•p1
NYC-WTC 000123871
OCR can misread numbers and units. Confirm readings against the page image before using them.