NYC 9/11 Public Portal Document
Asbestos Abatement
materials.
e) If the Work is not approved, the Testing Laboratory will inform
Contractor who will then HEPA-vacuum and/or wet-clean the Work
Area. The Testing Laboratory will then perform a subsequent visual
observation. This process will continue until the Testing Laboratory
accepts the Work Area as clean.
f) Remove polyethylene banders from the walls of the Work Area.
Isolation barriers shall remain in place.
g) Perform a thorough HEPA-vacuuming of the Work Area.
h) The Testing Laboratoiy will conduct a visual ohsei-vation of the
Work Area to verify the absence of asbestos-containing waste
materials.
i) If the Work is not approved, the Testing Laboratory will inform
Contractor who will then HEPA-vacuum the Work Area. The
Testing Laboratory will then perform a subsequent visual
observation. This process will continue until the Testing Laboratoiy
accepts the Work Area as clean.
j) If results of air sampling perfonned during abatement activities
indicate airborne fiber concentrations of less that 0.01 fibers per
cubic centimeter, or the background level, whichever is greater, final
clearance air sampling is not required. The abatement action may be
considered complete.
k) Isolation Barrier Removal
(1) Upon receipt of acceptable observation results,
polyethylene sheeting and barrier tape shall be removed
and disposed accordingly as ACM.
(2) The area surrounding the abatement work place shall be
cleaned of any visible debris utilizing HEPA vacuum and
wet methods.
1) The Testing Laboratory will conduct final visual. Approval must
be granted prior to break down of decontamination facility and
contractor demobilization. Other Information: Extra time required
to clean Work Areas in order to achieve clearance criteria shall not
be considered grounds for an extension of time for contract
completion.
CAPITAL PROJECT NUMBER PO79201K 02081-83
100: CONTRACT DOCUMENTS REV. May 3,2000
- 83 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631332
NYC-WTC_000416844
OCR can misread numbers and units. Confirm readings against the page image before using them.