person than did the original, whenever possible.

Verified analysis This is a re-count of a TEM grid (same openings) or a PCM slide (Code = VA) (random fields) by a different laboratory than performed the original analysis. A detailed protocol for verified analysis in provided in NIST (1994).

For the purposes of this project, air samples will undergo re-preparation at a rate of at least 5% and re-analysis (different) at a rate of at least 5%. When a laboratory does not have sufficient trained analysts available to perform the needed re-analysis (different), re-analysis (same) may be used, but the re-analysis (same) must be performed at least 24 hours after the initial analysis.

Field-Based QC Samples

These are samples that are prepared in the field and submitted to the laboratory in a blind fashion. That is, the laboratory is not aware the sample is a QC sample, and should treat the sample in the same way as a field sample.

QC Sample Type Description

Field Blank This is a filter that is placed in a collection cassette for either a personal or a (Code = FB) stationary air monitor or a microvac, but through wliich no air is drawn. There is no field blank for dust. Field Duplicate This is a second sample of environmental medium collected at the same place (Code = FD) and at the same time as the primarj' sample. Field duplicates may be collected or for each type of medium (air, dust). For the purposes of this study, duplicate Field Replicate samples of air (i.e., two filters collected at the same time and same location (Code = REP) using different pumps and cassettes) are referred to as replicates rather than duplicates. Performance These are samples of a medium in which the concentration of the target analyte Evaluation Standards is known. In the case of asbestos, there are no adequate PE samples available (Code = PE-xx) forair (as a primary medium)', soil, dust, or debris. At present, the USEPA is working to develop PE samples for asbestos in soil, and these will be included in the study if they become available in time.

For the purposes of this project, field blanks will be submitted for air samples and dust samples at a rate of 5% (minimum number = 2). There are no field blanks for soil or dust.

Field replicates of air samples will also collected at a rate of approximately 5%. This will include samples from co-located stationary air monitors, and may also include samples obtained from

' Samples of asbestos deposited on MCE filters are available from NIST (NVLAP), but these filters contain chrysotile fibers only, and have a size distribution that is not similar to that observed for amphiboles.

NYC-WTC_000407788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →