NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Draft NYC WTC environmental monitoring chain

Machine-extracted title · confidence 41%

Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.

NYC-WTC_000454763–000454798
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(Code = RD) microscopist in the same laboratory than the individual who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist re-counts the slide at randomly selected fields.

Re-preparation This is a grid or a slide that is prepared from a new aliquot of the (Code = RP) same field sample as was used to prepare the original grid or slide. This is often referred to as a laboratory duplicate. Typically this is done within the same lab as did the original analysis, but a different lab may also prepare grids from a new piece of filter. If the re-preparation is done within a laboratory, the re-preparation and re-analysis should be done by a different person than did the original, whenever possible.

Verified analysis This is a re-count of a TEM grid (same openings) or a PCM slide (Code = VA) (random fields) by a different laboratory than performed the original analysis. A detailed protocol for verified analysis in provided in NIST (1994).

For the purposes of this project, air samples will undergo re-preparation at a rate of at least 5% and re-analysis (different) at a rate of at least 5%. When a laboratory does not have sufficient trained analysts available to perform the needed re-analysis (different), re-analysis (same) may be used, but the re-analysis (same) must be performed at least 24 hours after the initial analysis.

Field-Based QC Samples

These are samples that are prepared in the field and submitted to the laboratory in a blind fashion. That is, the laboratory is not aware the sample is a QC sample, and should treat the sample in the same way as a field sample.

QC Sample Type Description

Field Blank This is a filter that is placed in a collection cassette for either a personal or a (Code = FB) stationary air monitor or a microvac, but through which no air is drawn. There is no field blank for dust. Field Duplicate This is a second sample of environmental medium collected at the same place (Code = FD) and at the same time as the primary sample. Field duplicates may be or collected for each type of medium (air, dust). For the purposes of this study, Field Replicate duplicate samples of air (i.e., two filters collected at the same time and same (Code = REP) location using different pumps and cassettes) arc referred to as replicates rather than duplicates.

Samples of asbestos deposited on MCE filters are available from NIST (NVLAP), but these filters contain chrysotile fibers only, and have a size distribution that is not similar to that observed for amphiboles.

CITY_21MC100_0 06455410

NYC-WTC_000454789

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454789Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →