Draft: environmental monitoring plan for WTC debris

Machine-extracted title · confidence 50%

Draft plan for environmental monitoring of exposure to fibers after WTC collapse.

NYC-WTC_000302886–000302921
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Re-preparationThis is a grid or a slide that is prepared from a new aliquot of the (Code = RP) same field sample as was used to prepare the original grid or slide. This is often referred to as a laboratory duplicate. Typically this is done within the same lab as did the original analysis, but a different lab may also prepare grids from a new piece of filter. If the re-preparation is done within a laboratory, the re-preparation and re-analysis should be done by a different person than did the original, whenever possible.

Verified analysis This is a re-count of a TEM grid (same openings) or a PCM slide (Code = VA) (random fields) by a different laboratory than performed the original analysis. A detailed protocol for verified analysis in provided in NIST (1994).

For the purposes of this project, air samples will undergo re-preparation at a rate of at least 5% and re-analysis (different) at a rate of at least 5%. When a laboratory does not have sufficient trained analysts available to perform the needed re-analysis (different), re-analysis (same) may be used, but the re-analysis (same) must be performed at least 24 hours after the initial analysis.

Field-Based QC Samples

These are samples that are prepared in the field and submitted to the laboratory in a blind fashion. That is, the laboratory is not aware the sample is a QC sample, and should treat the sample in the same way as a field sample.

QC Sample Type Description

Field Blank This is a filter that is placed in a collection cassette for either a personal or a (Code = FB) stationary air monitor or a microvac, but through which no air is drawn. There is no field blank for dust.

Field Duplicate This is a second sample of environmental medium collected at the same place (Code = FD) and at the same time as the primary sample. Field duplicates may be collected or for each type of medium (air, dust). For the purposes of this study, duplicate Field Replicate samples of air (i.e., two filters collected at the same time and same location (Code = REP) using different pumps and cassettes) are refened to as replicates rather than duplicates.

Performance These are samples of a medium in which the concentration of the target Evaluation Standards analyte is known. In the case of asbestos, there are no adequate PE samples (Code = PE-xx) available for air (as a primary medium)', soil, dust, or debris. At present, the USEPA is working to develop PE samples for asbestos in soil, and these will be included in the study if they become available in time.

' Samples of asbestos deposited on MCE filters are available from NIST (NVLAP), but these filters contain chrysotile fibers only, and have a size distribution that is not similar to that observed for amphiboles.

CITY_21MC100_009029051

NYC-WTC_000302912

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302912Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →