NYC 9/11 Public Portal Document

These are samples prepared in or re-analyzed by the laboratory.

Recount (same) This is a TEM grid or a PCM slide that is re-examined by the same (Code = RS) microscopist who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist simply re-counts the slide at randomly selected fields

Recount (different) This is a TEM grid or a PCM slide that is re-examined by a different (Code = RD) microscopist in the same laboratory than the individual who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist re­ counts the slide at randomly selected fields.

Re-preparation This is a grid or a slide that is prepared from a new aliquot of the (Code = RP) same field sample as was used to prepare the original grid or slide. This is often referred to as a laboratory duplicate. Typically this is done within the same lab as did the original analysis, but a different lab may also prepare grids from a new piece of filter. If the re-preparation is done within a laboratory, the re-preparation and re-analysis should be done by a different person than did the original, whenever possible.

Verified analysis This is a re-count of a TEM grid (same openings) or a PCM slide (Code = VA) (random fields) by a different laboratory than performed the original analysis. A detailed protocol for verified analysis in provided in NIST (1994).

For the purposes of this project, air samples will undergo re-preparation at a rate of at least 5% and re-analysis (different) at a rate of at least 5%. When a laboratory does not have sufficient trained analysts available to perform the needed re-analysis (different), re-analysis (same) may be used, but the re-analysis (same) must be performed at least 24 hours after the initial analysis.

Field-Based QC Samples

These are samples that are prepared in the field and submitted to the laboratory in a blind fashion. That is, the laboratory is not aware the sample is a QC sample, and should treat the sample in the same way as a field sample.

QC Sample Type Description

CONFIDENTIAL CITY_21MC100_009513629 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241808

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241808Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →