NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 59 pages

Confidential WTC environmental monitoring draft

Machine-extracted title · confidence 41%

Draft confidential sampling and exposure monitoring plan for WTC debris events.

NYC-WTC_000241781–000241839
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Number of structures longer than 5 urn counted is > 20 OR number of grid openings equals 50 PCM 100 fields are viewed OR 100 fibers are counted (but not less than 20 fields must be counted)

At the low end, based on the assumed flow rates and sampling durations described previously, these rules will allow quantification of combined cancer risks (lung cancer plus mesothelioma) at or below a level of 1E-04 for all scenarios and methods except for routine exposures of residents based on the Berman and Crump risk assessment methodology (assuming 30% of the protocol structures are longer than 10 urn). In this case, it would be necessary to count 500-1000 grids to establish a 95% UCL on low fiber counts that approaches 1E-04.

At the high end, a plot of the ratio of the 95% UCL on fiber count as a function of the number of fibers counted reveals that there is relatively little reduction in uncertainty after the number of fibers reaches 15-20. Thus, for the TEM method, counting will stop if 20 structures are observed. For PCM, because counting is faster than for TEM, the stopping point is 100 fibers.

Flower or Vegetable Garden Soil Samples

Where applicable garden soil samples will be evaluated for asbestos content using one or more methods to be specified after completion of a study specifically designed to evaluate the relative advantages and limitations of a number of alternative methods for measuring asbestos in soil and other solid media (EPA 2000c).

Bulk Dust Samples

Bulk dust samples will be evaluated for asbestos content using polarized light microscopy (PLM), in accord with SOP NIOSH 9002. Other methods may also be used, as needed, and considering the results of a study designed to evaluate the relative strengths and weaknesses of a number of alternative methods for measuring asbestos in dust and other solid media (EPA 2000c).

B5. QUALITY CONTROL

Quality Control (QC) is a component of the QA Plan, and consists of the collection of data that allow a quantitative evaluation of the accuracy and precision of the field data collected during the project. QC samples that will be collected during this project include the following types of samples.

Laboratory-Based QC Samples

CONFIDENTIAL, CITY_2IMCl00_009513628 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241807

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241807Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →