NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 34 pages

Environmental monitoring draft for WTC collapse exposure, NYC

Machine-extracted title · confidence 44%

Draft NYC EH monitoring document on exposure to fibers after WTC collapse.

NYC-WTC_000407762–000407795
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

For PCM, because counting is faster than for TEM, the stopping point is 100 fibers.

Flower or Vegetable Garden Soil Samples

Where applicable garden soil samples will be evaluated for asbestos content using one or more methods to be specified after completion of a study specifically designed to evaluate the relative advantages and limitations of a number of alternative methods for measuring asbestos in soil and other solid media (EPA 2000c).

Bulk Dust Samples

Bulk dust samples will be evaluated for asbestos content using polarized light microscopy (PLM), in accord with SOP NIOSH 9002. Other methods may also be used, as needed, and considering the results of a study designed to evaluate the relative strengths and weaknesses of a number of alternative methods for measuring asbestos in dust and other solid media (EPA 2000c).

B5. QUALITY CONTROL

Quality Control (QC) is a component of the QA Plan, and consists of the collection of data that allow a quantitative evaluation of the accuracy and precision of the field data collected during the project. QC samples that will be collected during this project include the following types of samples.

Laboratory-Based QC Samples These are samples prepared in or re-analyzed by the laboratory.

Recount (same) This is a TEM grid or a PCM slide that is re-examined by the same (Code = RS) microscopist who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist simply re­ counts the slide at randomly selected fields

Recount (different) This is a TEM grid or a PCM slide that is re-examined by a different (Code = RD) microscopist in the same laboratory than the individual who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist re-counts the slide at randomly selected fields.

Re-preparation This is a grid or a slide that is prepared from a new aliquot of the (Code = RP) same field sample as was used to prepare the original grid or slide. This is ofl;en referred to as a laboratory duplicate. Typically this is done within the same lab as did the original analysis, but a different lab may also prepare grids from a new piece of filter. If the re-preparation is done within a laboratory, the re-preparation and re-analysis should be done by a different

NYC-WTC_000407787

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407787Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →