NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

WTC sampling plan draft, NYC EH

Machine-extracted title · confidence 42%

Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.

NYC-WTC_000241745–000241780
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

" Allan Goldberg - Nyc-wtc sampling plan v2.doc Page^

Bulk dust samples will be evaluated for asbestos content using polarized light microscopy (PLM), in accord with SOP NIOSH 9002. Other methods may also be used, as needed, and considering the results of a study designed to evaluate the relative strengths and weaknesses of a number of alternative methods for measuring asbestos in dust and other solid media (EPA 2000c). I- B5. QUALITY CONTROL

Quality Control (QC) i.s a component of the QA Plan, and consists of the collection of data that allow a quantitative evaluation of the accuracy and precision of the field data collected during the project. QC samples that will be collected during this project include the following type.s of samples.

LahDi atory-liasetl QC Samples I These are samples prepared in or re-analyzed by the laboratory.

Recoum(sarne) This is a TEM grid or a PCM slide that is re-examined by rhe same (Code = RS) microscopist who performed the initial examination. In the case of a TEM grid, the microscopist returns to the same grid openings as were counted in the original examination, tn the case of PCM, the microscopisi simply re-counts the slide al randomly selected fields

Recount (different) This is a TEM grid or a PCM slide that is re-examined by a different (Code = RD) microscopist in the same laboratory than the individual who performed the initial examination. In the case of a TEM grid, the ( microscopist returns to the same grid openings as were counted in the original examination. In the case of PCM, the microscopist re-counts the slide at randomly selected fields.

Re-preparation This is a grid or a slide that is prepared from a new aliquot of the (Code = RI’) same field sample as wa,s used to prepare the original grid or slide. This is often referred to as a laboratory duplicate. Typically this is done within the same lab as did the original analysis, but a different lab may also prepare grids from a new piece of filter. If the re-preparation is done within a laboratory, the re-preparation and re-analysis should be done by a different person than did the original, whenever possible.

Verified analysi.s This is a re-count of a TEM grid (same openings) or a PCM slide (Code == VA) (random fields) by a different laboratory than performed the original analysis. A detailed protocol for verified analysis in provided in I NIST (1994).

For the purpose.s of this project, air samples will undergo re-preparation at a rate of at least 5%

NYC-WTC_000241771

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241771Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →