NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

WTC sampling plan draft, NYC EH

Machine-extracted title · confidence 42%

Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.

NYC-WTC_000241745–000241780
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

i Allan Goldberg - Nyc-wtc sampling plan v2.doc Page’is]

and re-analysis (different) at a rate of at least 5%. When a laboratory does not have sufficient trained analyst.s available to perfomi the needed re-analysis (different), re-analysis (same) may be used, but the re-analysis (same) must be performed at least 24 hours after the initial analysis.

Field-liased QC Samples

These are samples that are prepared in the field and submitted to the laboratory in a blind fashion. That is, the laboratory is not aware the sample is a QC sample, and should treat the sample in the same way as a field sample.

I QC Sample Type Description I

Field Blank This is a filter that i.s placed in a collection cassette for either a personal or a (Code = FB) stationary air monitor or a microvac, but through which no air is drawn. There is no field blank for dust.

Field Duplicate This is a second sample of environmental medium collected at the same place i (Code = FD) and at the same time a.s the primary sample. Field duplicates may be or collected for each type of medium (air, dust). For the purposes of this study. Field Replicate duplicate samples of air (i.e., two filters collected at the same time and same (Code = REP) location using different pumps and cassettes) are referred to as replicates rather than duplicates.

Performance These are samples of a medium in which the concentration of the target i. Evaluation Standards analyte is known. In the case of asbestos, there are no adequate PE sample;; (Code = PE-xx) available for air (as a primary medium)', soil, dust, or debris. At present, the USEPA is working to develop PE samples for asbestos in soil, and these will be included in the study if they become available in time.

For the purposes of thi.s project, field blanks will be submitted for air samples and dust sample;; at a rate of 5% (minimum number = 2). There are no field blanks for soil or dust.

Field replicates of air samples will also collected at a rate of approximately 5%. This will include samples from co-located stationary air monitors, and may also include samples obtained from personal air monitors using a flow splitter, when feasible.

Although filed duplicate samples of debris or dust will be collected from some locations as parr of this program, it is important to stress that these will not be evaluated as QC samples, since there are no criteria to judge whether the agreement between sample,s is within some pre-define acceptance limit. Rather, duplicate samples of these media will be used to gain undersianOinu of

' Samples of asbestos deposited on MCE filters are available from NIST (NVLAP), but these filters contain chrysotile fibers only, and have a size distribution that is not similar to that observed for amphiboles.

NYC-WTC_000241772

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241772Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →