NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

WTC sampling plan draft, NYC EH

Machine-extracted title · confidence 42%

Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.

NYC-WTC_000241745–000241780
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Allan Goldberg - Nyc-wtc sampling plan v2.doc

Slopping Rules

The analytical sensitivity and detection limit of microscopic methods such as TEM and PCM are a function of the volume of air drawn through the filter and the number of grids openings or fields counted. In principle, any required sensitivity or detection limit can be achieved simply by I increasing number of grid openings or fields examined. Likewise, statistical uncertainty around i, the number of fibers observed can be reduced simply by counting more and more fibers. i- Because of the open-ended nature of thi.s situation, stopping rules are needed to specify when microscopic examination should end, both at the low end (zero or very few fibers observed) and at the high end (many fibers observed). For the purposes of this investigation, the following stopping rules will be employed:

iVIctlioil Count Until

TEM Number of structures longer than 5 urn counted is ’ 20 OR number of grid openings equals 50 PCM 100 fields are viewed OR 100 fibers are counted (but not less than 20 fields must be counted)

At the low end, based on the assumed flow rates and sampling durations described previously, these rules will allow quantification of combined cancer risks (lung cancer plus mesothelioma) al or below a level of 1E-04 for al! scenarios and methods except for routine exposures of rcsidenis based on the Berman and Crump risk assessment methodology (assuming 30% of the protocol structures are longer than 10 um). In this case, it would be necessary to count 500-1000 grids to establish a 95% UCL on low fiber counts that approaches 1 E-04.

At the high end, a plot of the ratio of the 95% UCL on fiber count as a function of the number of fibers counted reveals that there is relatively little reduction in uncertainty after the number of fibers reaches 15-20. Thus, for the TEiM method, counting will stop if 20 structures are observed. For PCM, because counting is faster than for TEM, the stopping point is 100 fibers.

Flower or Fegenihle Garden Soil Samples

Where applicable garden soil samples will be evaluated for asbestos content using one or more methods to be specified after completion of a study specifically designed to evaluate the relative advantages and limitations of a number of alternative methods for measuring asbestos in soil and other solid media (EPA 2000c).

Bulk Dust Samples t

NYC-WTC_000241770

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241770Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →