NYC 9/11 Public Portal Document

Counting Rules

The microscopist will record all observations on a TEM or PCM Laboratory Microscopy Results Form, which are included in Appendix C. For TEM, for each fiber that is characterized in accord with the applicable counting rules, the microscopist will record the size (length, thickness) and type (chrysotile, amosite, amphibole, or non-asbestos) of the fiber. These data will then serve to support calculation of fiber counts in specified size and type categories ("bins"). For PCM, only the number (and not the dimensions or type) of fibers which meet the counting rules will be recorded.

For TEM, the counting rules specified in ISO 10312 will be used for all air and dust samples. In addition, air samples collected by the stationary air filter in the central location of the apartment before, during and after the active cleaning and simulated restoration scenarios will be analyzed according to the AHERA method by a nearby field laboratory. This analysis is needed is to shorten the analytical turn-around time for these samples, since the results from these samples are required to ensure that levels in the apartment are safe before allowing the residents to return.

For PCM, the counting rules established by NIOSH 7400 (Revision 2) will be used for all samples. Differential counting (i.e., excluding fibers which the analyst suspects are not asbestos) will not be used.

Stopping Rules

The analytical sensitivity and detection limit of microscopic methods such as TEM and PCM are a function of the volume of air drawn through the filter and the number of grids openings or fields counted. In principle, any required sensitivity or detection limit can be achieved simply by increasing number of grid openings or fields examined. Likewise, statistical uncertainty around the number of fibers observed can be reduced simply by counting more and more fibers. Because of the open-ended nature of this situation, stopping rules are needed to specify when microscopic examination should end, both at the low end (zero or very few fibers observed) and at the high end (many fibers observed). For the purposes of this investigation, the following stopping rules will be employed:

Method Count Until

TEM Number of structures longer than 5 urn counted is * 20 OR number of grid openings equals 50 PCM 100 fields are viewed OR 100 fibers are counted (but not less than 20 fields must be counted)

NYC-WTC_000242006

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242006Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →