‘ Allan Goldberg - Nyc-wtc sampling plan v2.doc Page 2^

As discussed above, all air and dust sample.s collected during this study will be analyzed iisiiie both PCM and TEM methods.

Direct VA' /ndireci Preparation Met/uxls

For both TEM and PCM, two alternative approaches are available; “direct” and “indirect” analysis. In direct analysis, the sample is prepared with minimal handling, generally by piacmu the test material directly under the microscope for examination. However, this approach may sometimes be inadequate because a) the fibers are accompanied by an excessive level of nori- f asbestos material, or b) the concentration of asbestos fibers is either too low or too high for reliable quantification. In these cases, an indirect approach may be used. In the indirect method. the sample is generally diluted, concentrated, and/or treated to remove interferences, such that the asbestos fibers can be more reliably quantified. However, because indirect preparation steps may alter fiber morphology and/or may alter fiber recovery, indirect sampling may introduce uncertainty into rhe results.

For the purposes of this study, direct preparations are strongly preferred for all air filters, and a direct preparation will be made and examined for all air samples. When reliable fiber counts cannot be obtained for one or both method.s due to interfering materials, an indirect preparation will be made and rhe indirect preparation will be re-analyzed by both methods. For dust, only the secondary preparation method will be used.

Counting Rules

The microscopist will record all observations on a TEM or PCM Laboratory Microscopy Results Form, which are included in Appendix C. For TEM, for each fiber that is characterized in accord with the applicable counting rules, the microscopist will record the size (length, thickness) and type (chrysotile, amosite, amphibole, or non-asbestos) of the fiber. These data will then serve io support calculation of fiber counts in specified size and type categories ("bins"). For PCM , only the number (and not the dimensions or type) of fibers which meet the counting rules will be recorded.

For TEM, the counting rules specified in ISO 10312 will be used for all air and dust samples. In addition, air samples collected by the stationary air filter in the central location of the aparimeni before, during and after the active cleaning and simulated restoration scenarios will be anaiv/e.i according to the AHERA method by a nearby field laboratory. This analysis is needed is to shorten the analytical turn-around time for these samples, since the results from these samples are required to ensure that levels in the apartment are safe before allowing the residents to return.

For PCM, the counting rules established by NIOSH 7400 (Revision 2) will be used for all samples. Differential counting (i.e., excluding fibers which the analyst suspects are not asbestos) will nor be used.

NYC-WTC_000241769

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241769Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →