r Tribeca Tower -105 Duane Street ATC Project No.: 09622-0014 Related Management Company, L.P. February 11, 2002 Page 5

January 2 & 3, 2002 Floor Apartments Floor Apartments Floor Apartments 36 19 LUZ 35 18 51 34 17 50 33 16 49 32 15 48 31 14 47 30 12 46 29 h 11 d 45 28 10 44 27 9 43 26 8 42 25 7 41 24 6 40 23 5 39 22 4 38 21 1 37 a 20

Fiberglass in Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence of a specific ambient air standard for fiberglass, ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of Jess than 0.01 fibers per cubic centimeter (o.ol f/cc^). In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, it is ATC’s opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy

PCB’s in Air One ambient air sample collected within the lobby and analyzed for PCB’s recorded analytical results less than analytical detection limit.

CITY_21MC100_010173375

NYC-WTC_000407272

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407272Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365363

Ambient air sampling and visual observations after World Trade Center collapse, Feb 2002.

Similar indexed content

NYC-WTC_000209856

Summary report of ambient air sampling and visual observations conducted at Tribeca Park following the World Trade Center collapse.

Similar indexed content

NYC-WTC_000365779

ATC sampling memo documenting asbestos sampling in hallways and mechanical room, Dec 2001.

Similar indexed content

NYC-WTC_000365799

ATC sampling memo detailing 14 ambient air samples at Tribeca Towers, Jan 2002.

Similar indexed content

Compare copies and versions →