Fiberglass in Air via PCM
Twelve ambient air samples collected within the common areas lobby were analyzed for
fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected
recorded fiber levels less than 0.01 f/cc
In the absence of a specific ambient air standard for fiberglass, ATC has selected as a criteria
for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an
asbestos abatement action of an average of less than 0.01 fibers per cubic centimeter (o.ol
f/cc^).
In conclusion, based upon the analytical results for fiberglass recording fiber concentrations
below the NYC acceptable airborne clearance requirement following an abatement action, it is
ATC's opinion that the ambient air samples collected throughout the building meet an
acceptable criterion for re-occupancy
PCB’s in Air
One ambient air sample collected within the lobby and analyzed for PCB’s recorded analytical
results less than analytical detection limit.