10 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Tribeca Tower asbestos air sampling summary, Dec 11, 2001
Machine-extracted title · confidence 48%Summary of ATC asbestos air sampling results and dust observations at Tribeca Tower.
NYC-WTC_000363404–000363406The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Ambient Air Sampling ASSOCIATES INC.
Fiberglass in Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence of a specific ambient air standard for fiberglass, ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of less than 0.01 fibers per cubic centimeter (o.ol f/cc®). In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, it is ATC’s opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy
PCB’s in Air One ambient air sample collected within the lobby and analyzed for PCB’s recorded analytical results less than anal^ical detection limit.
Indoor Air Quality The lAQ evaluation included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (CO2), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as residential units. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications: • Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); • Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
PARAMETER TARGET LEVEL SSSk-noN Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon IMonoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62)_______________ Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in PMio)____________ meter of air (pg/m^) ASHRAE 62)_______________ Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55
CITY_21MC100_002847954
NYC-WTC_000363405
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000363386
Summary of sampling observations and ambient air monitoring at Tribeca Tower.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209856
Summary report of ambient air sampling and visual observations conducted at Tribeca Park following the World Trade Center collapse.
11 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000365363
Ambient air sampling and visual observations after World Trade Center collapse, Feb 2002.
14 shared non-person entities · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000269013
Summary of observations and air sampling during Tribeca Tower inspections.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357527
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354099
ATC inspection summary of dust/debris in 406 units; no widespread deposition found.
13 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337568
Summary of observations and ambient air sampling at aTribeca building site.
12 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318568
Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199569
Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.
12 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454704
TEM analysis of lead-in-dust wipes inside PS 89M and outdoor playground, Jan 2002.
10 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096047
Summary of dust characterization survey findings at the site in October 2001 including asbestos detection.
3 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000269013
Summary of observations and air sampling during Tribeca Tower inspections.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357527
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199569
Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Summary of observations and air sampling during Tribeca Tower inspections.
Similar indexed content
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
Similar indexed content
ATC inspection summary of dust/debris in 406 units; no widespread deposition found.
Similar indexed content
NYC-WTC_000337568
Summary of observations and ambient air sampling at aTribeca building site.
Similar indexed content
Similar indexed content