Tribeca Tower asbestos air sampling summary, Dec 11, 2001

Machine-extracted title · confidence 48%

Summary of ATC asbestos air sampling results and dust observations at Tribeca Tower.

NYC-WTC_000363404–000363406
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Sampling ASSOCIATES INC.

Fiberglass in Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence of a specific ambient air standard for fiberglass, ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of less than 0.01 fibers per cubic centimeter (o.ol f/cc®). In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, it is ATC’s opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy

PCB’s in Air One ambient air sample collected within the lobby and analyzed for PCB’s recorded analytical results less than anal^ical detection limit.

Indoor Air Quality The lAQ evaluation included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (CO2), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as residential units. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications: • Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); • Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

PARAMETER TARGET LEVEL SSSk-noN Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon IMonoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62)_______________ Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in PMio)____________ meter of air (pg/m^) ASHRAE 62)_______________ Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55

CITY_21MC100_002847954

NYC-WTC_000363405

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363405Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000269013

Summary of observations and air sampling during Tribeca Tower inspections.

Similar indexed content

NYC-WTC_000357527

Summary of observations and air/dust sampling at Tribeca Tower for asbestos.

Similar indexed content

NYC-WTC_000354099

ATC inspection summary of dust/debris in 406 units; no widespread deposition found.

Similar indexed content

Compare copies and versions →