← Document results/DEP Box 51/105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER
Document / 165 pages

DOH/DEP asbestos fact sheet draft, 105 Duane Street

Machine-extracted title · confidence 95%

Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.

NYC-WTC_000125845–000126009

Folder label: “105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER

Page image
Scanned page image, NYC-WTC_000125923
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

t^ <~ Ambient Air Sampling

Fiberglass in Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass g using the Phase Contrast Microscopy (PCM) analytical Y method. All samples P collected recorded fiber levels less than 0.01 f/cc In the absence of a specific ambient air standard for fiberglass, ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of less than 0.01 fibers per cubic centimeter (o.o1 f/cc2), In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, it is ATC's opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy

PCB's in Air One ambient air sample collected within the lobby arid analyzed for PCB's recorded analytical results less than analytical detection limit.

Indoor Air Quality The IAQ evaluation included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (CO2), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as residential units. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications: i Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); • Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

._. .w, PARAMETL R TARGET LL E AGENCY OR 0RGANIZA i N Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in CO ASHRAE 62) Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in (PM,r) meter of air / ASHRAE 62) Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 — 60 °io ASHRAE 55

NYC-WTC 000125923

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125923Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →