NYC 9/11 Public Portal Document
1700 Elm Street - Suite 200
Minneapolis, MN 55414
/J^ce Analytical Tel; 612-607-1700
Fax- 61?- 607-6444
Method 8290 Analysis Results
I Client - ATC ASSOCIATES
Client's Sample ID ATC-0424-STY-DX2
Lab Sample ID 103499935
Filename F20518A_06
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/24/2002
ICAL Date 05/04/2002 Received 04/30/2002
CCal Filename(s) F20518A_01 & F20518A_17 Extracted 05/06/2002
Method Blank ID BLANK-1610 Analyzed 05/18/2002 20:15
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0040 0.0020 J 2,3,7,8-TCDF-13C 2.00 74
Total TCDF 0.0470 0.0020 2,3,7,8-TCDD-13C 2.00 66
1,2,3.7,8-PeCDF-13C 2.00 57
2,3,7,8-TCDD ND 0.0039 A 2,3,4.7,8-PeCDF-13C 2.00 57
Total TCDD 0.0440 0.0020 1,2,3,7,8-PeCDD-13C 2.00 54
1,2,3,4,7,8-HxCDF-13C 2.00 101
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6.7,8-HxCDF-13C 2.00 85
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6.7,8-HxCDF-13C 2.00 79
Total PeCDF 0.0220 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 68
1,2,3,4,7,8-HxCDD-13C 2.00 90
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 77
Total PeCDD 0.0340 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 57
1,2,3,4,7,8,9-HpCDF-13C 2.00 44
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 48
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 44
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0620 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7.8-TCDD-37CI4 0.20 73
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.2000 0.0100
1,2,3,4,6,7,8-HpCDF 0.0200 0.0100 J Total 2,3,7,8-TCDD
1,2,3.4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00092 ng/m2
Total HpCDF 0.0200 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0260 0.0100 J
Total HpCDD 0.0560 0.0100
OCDF ND 0.0200
OCDD 0.0630 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3.7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1056899
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003797500
NYC-WTC_000406243