NYC 9/11 Public Portal Document
1700 Elm Street - Suite 200
/'^J^aceAnalytical^ Minneapolis, MN 55414
Tel; 612-607-1700
Fax- 612- 607-6444
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0308-M833-DX2
Lab Sample ID 103384798
Filename U20326B_14
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/08/2002
I CAL Date 03/25/2002 Received 03/12/2002
CCal Filename(s) U20326B_02 & U20326B_17 Extracted 03/21/2002
Method Blank ID BLANK-1528 Analyzed 03/27/2002 02:40
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0020 A 2,3,7,8-TCDF-13C 2.00 75
Total TCDF 0.014 0.0020 2,3,7,8-TCDD-13C 2.00 71
1,2,3,7,8-PeCDF-13C 2.00 74
2,3,7,8-TCDD ND 0.0034 A 2,3,4,7,8-PgCDF-13C 2.00 72
Total TCDD 0.017 0.0020 1,2,3,7,8-PeCDD-13C 2.00 71
1,2,3,4,7,8-HxCDF-13C 2.00 111
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 85
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 86
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 86
1,2,3.4,7,8-HxCDD-13C 2.00 117
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 77
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 86
1,2,3,4,7,8,9-HpCDF-13C 2.00 72
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 79
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 69
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7.8-TCDD-37CI4 0.20 80
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.012 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00029 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.017 0.0100 J
Total HpCDD 0.017 0.0100 J
OCDF ND 0.0200
OCDD 0.120 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055017
REPORT OF LABORATORY ANALYSES
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002898129
NYC-WTC_000402659
OCR can misread numbers and units. Confirm readings against the page image before using them.