NYC 9/11 Public Portal Document
1700 Elm Street - Suite 200
Minneapolis, MN 55414
~ /Z^ceAnalvticar
-------- i
Tel: 612-607-1700
Fax: 612- 607-6444
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0308-M833-DX1
Lab Sample ID 103384780
Filename U20326B_13
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/08/2002
ICAL Date 03/25/2002 Received 03/12/2002
CCal Filenamefs) U20326B_02 & U20326B_17 Extracted 03/21/2002
Method Blank ID BLANK-1528 Analyzed 03/27/2002 01:52
Native Cone EMPC LRL Dnternal ng's Percent
Ssomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0029 A 2,3,7,8-TCDF-13C 2.00 66
Total TCDF ND 0.0020 2,3,7,8-TCDD-13C 2.00 68
1.2,3,7,8-PeCDF-13C 2.00 66
2,3,7.8-TCDD ND 0.0033 A 2,3,4,7,8-PeCDF-13C 2.00 64
Total TCDD 0.0061 0.0020 J 1,2,3,7,8-PeCDD-13C 2.00 64
1,2,3.4,7,8-HxCDF-13C 2.00 107
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 86
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 87
Total PeCDF ND 0.0100 1,2,3,7,8.9-HxCDF-13C 2.00 81
1,2,3.4,7,8-HxCDD-13C 2.00 116
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 88
1,2,3,4,7,8,9-HpCDF-13C 2.00 77
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 82
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 70
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 79
1,2,3.6,7,8-HxCDD ND 0.0100
1,2,3.7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3.4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00017 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0120 0.0100 J
Total HpCDD 0.0120 0.0100 J
OCDF ND 0.0200
OCDD 0.0470 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 02-1055017
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002898128
NYC-WTC_000402658
OCR can misread numbers and units. Confirm readings against the page image before using them.