NYC 9/11 Public Portal Document
1700 Elm Street - Suite 200
/'^J^aceAnal^ Minneapolis, MN 55414
Tel: 612-607-1700
Fax: 612- 607-6444
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0308-M833-DX3
Lab Sample ID 103384806
Filename U20327A_03
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/08/2002
ICAL Date 03/25/2002 Received 03/12/2002
CCal Filename(s) U20326B_17 & U20327A_15 Extracted 03/21/2002
Method Blank ID BLANK-1528 Analyzed 03/27/2002 07;30
Native Cone EMPC LRL InternaS ng'§ Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0039 A 2.3,7,8-TCDF-13C 2.00 70
Total TCDF 0.0070 0.0020 J 2,3,7,8-TCDD-13C 2.00 70
1,2,3,7,8-PeCDF-13C 2.00 71
2,3,7,8-TCDD ND 0.0077 A 2,3,4,7,8-PeCDF-13C 2.00 73
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 74
1,2,3,4,7,8-HxCDF-13C 2.00 102
1.2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 91
2.3.4,7,8-PeCDF ND 0.0100 2,3.4,6,7,8-HxCDF-13C 2.00 90
Total PeCDF ND 0.0100 1,2,3.7,8,9-HxCDF-13C 2.00 85
1,2,3,4,7,8-HxCDD-13C 2.00 110
1,2,3,7.8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 93
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 96
1,2,3,4,7,8,9-HpCDF-13C 2.00 82
1,2,3,4.7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 86
1,2.3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 74
2,3,4,6,7,8-HxCDF ND 0.0100
1.2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 76
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1.2,3,4,7.8.9-HpCDF ND 0.0100 Equivalence: 0.00024 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.023 0.0100 I
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.2400 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055017
REPORT OF LABORATORY ANALYSES
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002898130
NYC-WTC_000402660