NYC 9/11 Public Portal Document
1700 Elm Street ■ Suite 200
Minneapolis, MN 55414
TM
^ace Analytical Method 8290 Analysis Results
Tel; 612-607-1700
FflX; 612- B07-6444
Client - ATC
I Client's Sample ID ATC-0427-STY-DX18
Lab Sample ID 103513404
Filename F20523A_16
Injected By BAL
Total Amount Extracted 0.38 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Fiienam©(s) F20523A_05 & F20523A_20 Extracted 05/20/2002
Method Blank ID Bl-ANK-1633 Analyzed 05/24/2002 01:08
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7.8-TCDF 29 5.3 E 2,3,7.8-TCDF-13C 2.00 85
Total TCDF 440.0 5.3 2,3,7,8-TCDD-13C 2.00 76
1,2,3.7,8-P0CDF-13e 2.00 76
2,3,7,8-TCDD 9.2 5.3 J 2.3,4,7,8.PeCDF-13C 2.00 74
Total TCDD 720.0 5.3 1,2,3,7,8-PeCDD-l3C 2.00 66
1.2,3,4,7,8-HxCDF-13C 2.00 77
1.2,3,7,8-PeCDF 30.0 26.0 J 1,2,3,6,7,8-HxCDF-13C 2.00 86
2,3,4,7,8-PeCDF 58.0 26.0 J 2,3,4.6.7,a-HxCDF-13C 2.00 93
Total PeCDF 370.0 26.0 1,2,3,7,8,9-HxCDF-13C 2.00 90
1,2,3,4.7,8-HxCDD-13C 2.00 91
1,2.3,7,8-PeCDD 28 26.0 I 1,2,3.6,7,8-HxCDD-13C 2.00 86
Total PeCDD 420.0 26.0 1,2,3,4,6,7,8-HpCDF-13C 2.00 61
1,2,3,4,7,8,9-HpCDF-13C 2.00 39 IP
1,2,3,4,7,8-HxCDF 72 26,0 E 1,2,3.4.6.7,8-HpCDD-13C 2.00 47
1,2.3,6,7,8-HxCDF 70 26.0 E OCDD-13C 4.00 56
2,3,4,6,7,8-HxCDF 55.0 26.0 J
1.2,3,7,8,9-HxCDF ND 26.0 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 370.0 26.0 1.2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 34.0 26-0 J 2.3,7,8-TCDD-37CI4 0.20 84
1,2,3,6,7,8-HxCDD 68.0 26.0 J
1,2,3,7,8,9-HxCDD 60.0 26.0 J
Total HxCDD 1100.0 26.0
1,2,3.4,6,7,8-HpCDF 280.0 26.0 Total 2,3.7,8-TCDD
1,2,3,4,7,8.9-HpCDF 47.0 26.0 J Equivalence: 76 ng/Kg
Total HpCDF 320.0 26.0 (Using ITE Factors)
1.2,3,4,6,7,8-HpCDD 680.0 26.0
Total HpCDD 1300.0 26.0
OCDF 370.0 53.0
OCDD 4100.0 53.0
Results reported on a total weight basis URL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,S-substituted isomers) I = interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-nolse measurement S - Saturated signal
J = Concentration detected Is below ths calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = Sa© Discussion
Report No.... 02-1057132