dvanced Environmental Corp. September 17, 2001

Mr. William Dacunto Managing Director of Operations Silverstein Properties 140 Broadway New York, New York 10005

Re: Asbestos Air Monitoring, 120 Wall Street, New York, NY

Dear Mr. Dacunto:

On September 16, 2001, Advanced Environmental Corp, performed air monitoring within various tenant floors within the above referenced building. Samples were collected within these floors to document the asbestos fiber concentration levels of the ambient air.

A total of eight (8) samples were collected and analyzed using the Transmission Electron Microscopy (TEM) method according to the EPA AHERA protocol. TEM with energy dispersive X-ray analysis is an analytical method that enables a fibers chemical composition to be identified.

At the present time, there are no non-industrial indoor air quality standards, or permissible exposure limits for airborne asbestos. This fiber specific protocol is generally utilized to determine clean air following a "large" abatement project. TEM sample analysis detects filter loads (the number of structures detected per square millimeter of collection media surface) which, if less than or equal to EPA-AHERA release criteria of 70 structures per square millimeter (s/mm^), determine whether or not the area is safe for re-occupancy.

A review of the analytical data shows, no structures were detected on all samples collected within 120 Wall Street, which is well below the EPA-AHERA release criteria of 70 s/mm\

In conclusion, the TEM sample analysis data show acceptable concentrations of fibrous materials in the ambient air.

If yoirhave any questions or need further clarification on air sampling methodology, please call me.

Sincerely,

Robert Fuorro Principal

1018.003 \\cpqserverl\data\aec\clients'isilverstem\l20 wall'air sampling 9-16-01 doc

347 Fifth Avenue, Suite 404, New York, New York 10016 Phone 212-545-1855 Fax 212-545-0757

CITY_21MC100_000621332 NYC-WTC_000390543

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390543Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air monitoring results, 120 Broadway

NYC-WTC_000306338

Memo detailing TEM air sampling on floors at 120 Broadway; notes lack of indoor air standards for asbestos.

Similar indexed content

NYC-WTC_000266138

DEC/Advanced Environmental memo detailing asbestos air monitoring at NY State Office floors.

Similar indexed content

Compare copies and versions →