Air quality sampling chain, 37 Murray Street

Machine-extracted title · confidence 55%

Chain of custody and air sampling report for 37 Murray Street; TEM analysis described.

NYC-WTC_000342863–000342864
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

7,C. ERODuR ass

J.C. Bioderick & Associates JCB Environmenral Engineers, Consukants &, Contractors Februar)? 7, 2002

Mr. Bob Dagger USAA PC Box 165 Nesconset, New York 11767

Re: Aggressive Asbestos Air Quality Sampling Report Letter Utilizing Transmission Electron Microscopy (TEM) Method of Analjvis at 37 Murray Street Apartment SA New York, New York Sampling Dates February 4,2002

JCB#: 02-2564

Dear Mr. Dagger;

J.C. Broderick & Associates, Inc, (JCB) was retained to perform aggressive asbestos in air sampling and analysis at the above referenced site subsequent to detailed cleaning activities performed by Branch Services- The air sampling was performed by a JCB New York State certified air sampUng technician. Samples were collected, chain of custody fonns prepared, and delivered to an independent ELAP certified laboratory for the presence of asbestos fibers by Transmission Electron Microscopy (TEM).

Aggressive air sampEng is a method of air sampling in which the person collecting the ait sample creates activity by the use of mechanical equipment during the sampling period to stir up settled dust to simulate activity in that area of the building. Pre-sampling agitation is conducted before the sampling is performed with the use of an electric powered forced air blower (leaf blower). The air blower is then directed against the furnishings, office equipment, walls, ceilings, floors, ledges and other surfaces. This is conducted for an extended period of time (at least five (5) minutes per 1,000 square feet of floor space),

Subsequent to the pre-sampling agitation 20 inch fans are placed throughout tlie test space (clean room). The fans will be operated on slow speed and are pointed towards the ceiling (at least one fan per 10,000 cubic feet of room space). The air sampling pumps are then turned on. When the air sampling is completed die sampling pomps are turned off, samples removed and the fans are then turned off. Aggressive air sampling is considered toe most representative of “worst case scenarios”.

The TEM analysis involves collecting airborne contaminates across the face of a polycarbonate or mixed cellulose ester filter. Again, air is drawn across pre-screcned filters by the use of portable large volume vacuum pumps. Prior to analyzing, the filter media is collapsed using an acetone vapor technique and then plasma etched. Then fiber structures are counted and analyzed using electron diffraction patterns and, in some cases, energy dispersive X-rays. Under this methodology, all fibers with a aspect ratio greater than 5:1 and a length of at least 0.5 micrometers are counted. TEM analysis can positively identify these fibers as asbestos or non-asbestos.

Tlie United States Environmental ProtEction Agency (US EPA), as indicated in 40 CFRPart 763 Section 90,

90-7 Colin Drive, Holbrook New York 11741 ‘Teb 63H19-0913 • 631-419-1327

CITY_21MC100_003008539

NYC-WTC_000342863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342899

JCB report on ambient asbestos in air sampling; TEM analysis coordination, Oct 2001.

Similar indexed content

Compare copies and versions →