J.C. Broderick & Associates
JCB Environmental Engineers, Consultants & Contractors
February 7, 2002
Mr.Bob Dagger
USAA
PC Box 165
Nesconset,New York 11767
Re: Aggressive Asbestos Air Quality Sampling Report Letter
Utilizing Transmisslun Electron Microscopy(TEM)Method of.Analysis at
37 Murray Street
Apartment5A
New York,New York
Sampling Dater February 4,2002
JCB#: 02-2564
Dear Mr. Dagger:
J.C. Broderick & Associates, Inc.(JCB)was retained to perform aggressive asbestos in air sampling and
analysis atthe abovereferenced site subsequentto detailed cleaning activities performed byBranch Services.
The air sampling was performed by a JCB Now York State certified air samplingtechnician. Samples were
collected, chain ofcustody forms prepared,and delivered to an Independent SLAP certified laboratory for
the presence of asbestos fibers by Transmission Electron Microscopy(TEM).
Aggressive air sampling is a method ofair sampling in which the person collecting the air sample creates
activity by the use of mechanical equipment during the sampling period to stir up settled dust to simulate
activity in that arm ofthe building. Pro-sampling agitation is conducted before the sampling is performed
with the use ofan electric powered forced air blower(leafblower). The air blower is theca directed against
the furnishings, office equipment, walls,ceilings, floors, ledges and other surfaces. This is conducted for
an extended period oftime(at least five(5)minutes per 1,000 square feet offloor space).
Subsequenttothe pre
agitation 20inchfans are placed throughoutthe testspace(clean room, The
-sampling
fans will be operated on slow speed and are pointed towards the ceiling( at least one fan per 10,000 cubic
feet of room space). The air sampling pumps are then turned on. When the air sampling is completed the
sampling pumps are turned off,samples removed and the fans are then turned off. Aggressive air sampling
is considered the most representative of "worst case scenarios".
The TEM analysis involves collecting airborne contaminates across the face of a polycarbonate or mixed
cellulose ester filter, Again, air is drawn across prescreened filters by the use of portable large volume
vacuum pumps. Priorto analyzing,the filter media is collapsed using an acetone vaportechnique and then
plasma etched. Then fiber structures are counted and analyzed using electron diffraction patterns and, in
some cases,energy dispersive X-rays. Under this methodology,allfibers with a aspectratio greaterthan 5:1
and a length ofat least 0.5 micrometers are counted.. TEM analysis can positively identify these fibers as
asbestos or non-asbestos.
Section 90,
The United States EnvironmentalProtection Agency(US EPA),as indicated in 40 CFTCPant763
947 Colin Drive, Holbrook New York 11741•Tel: 631-419-0913 ° Fsx 631.4191327