dvanced Environmental Corp.

September 19, 2001 .1 OCT 0 1 2001 I BY: Mr. William Dacunto Managing Director of Operations Silverstein Properties 140 Broadway New York, New York 10005

Re: 120 Broadway, Transmission Electron Microscopy Air Sample Results, New York, NY

Dear Mr. Dacunto:

On September 15 16, and 18, 2001, Advanced Environmental Corp, performed air monitoring within random areas of 120 Broadway. Samples were collected on random floors to document the asbestos concentration levels of the ambient air.

Please be advised that at the present time, there are no non-industrial indoor air quality standards, or permissible exposure limits for airborne asbestos.

Air sampling was conducted using the Transmission Electron Microscopy (TEM) method according to the EPA AHERA protocol. TEM with energy dispersive X-ray analysis is an analytical method that enables a fibers chemical composition to be identified, in this case asbestos. This fiber specific protocol is generally utilized to determine clean air following a "large" abatement project. TEM sample analysis detects filter loads (the number of structures detected per square millimeter of collection media surface) which, if the average of the sample counts is less than or equal to EPA-AHERA release criteria of 70 structures per square millimeter (s/mm^), the area is safe for re-occupancy.

Although the average counts within 120 Broadway were less than the EPA-AHERA release criteria of 70 structures, as a precaution, Silverstein Properties performed additional cleaning throughout the building. Re­ sampling was conducted in limited locations on September 18, 2001. Please be advised that no asbestos structures were found on these samples.

In conclusion, TEM sample data show acceptable concentrations of fibrous materials in the ambient air throughout the building.

If youmave any questions or need further clarification on air sampling methodology, please call me.

Sincefcely,

Robert Puorro Principal \\cpqserverl\data'aec\ciients\silverstein\120 bway'teni air sample wtc.doc

347 Fifth Avenue, Suite 404, New York, New York 10016 Phone 212-545-1855 Fax 212-545-0757

CITY_DEP_WORBY_CANNATA_SUBP_000007103

NYC-WTC_000306338

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306338Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000390543

TEM asbestos air monitoring results for multiple floors post-abatement.

Similar indexed content

NYC-WTC_000266138

DEC/Advanced Environmental memo detailing asbestos air monitoring at NY State Office floors.

Similar indexed content

Compare copies and versions →