JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone:(212)420-8119 Fax:(212)420-6092 Project No.: 01-2240 WSA Management ELAP Lab Code: 11029 Analyte; FIBERS 10O Ring Road Vtfest NIOSH and AIHA Lab Code: 100273 Date Received: 12/13/01 Garden City, NY 11530 NVLAP-Lab Code: 101953 Date Analyzed: 12/13/01

SUMMARY OF ANALYTICAL RESULTS - PCM Site: 80 John Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(niin) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB#

001 Ambient/ 4th Floor/ Apartment 4B/ Living Room/ 90 1352.7 2/100 <0.001<LOD 13-December East Wall/ Near Door A 9864

002 Ambient/ 4th Floor/Apartment 4B/ West 90 1352.7 2/100 <0.001<LOD 13-December Bedroom on West/ Near Closet A 9865

003 Ambient/ 12th Floor/Apartment 12F/ North East 90 1352.7 3/100 O.OOKLOD 13-December Bedroom on South/ Near Door A 9866

004 Ambient/ 12th Floor/ Apartment 12F/ Living 90 1352.7 2/100 <0.001<LOD 13-December Room/ Kitchen/ Counter South A 9867

005 Ambient/ 4th Floor/ Corridor/ South Side With 90 1352.7 4/100 O.OOKLOD 13-December South Wall A 9868

006 Ambient/ 4th Floor/ Corridor/ North Side With 90 1352.7 7/100 0^ 13-December North Wall A 9869

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOIDI = H.C.P. ( High Concentration of Particles) VCIID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 Instrumentation: Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Gulam Machniwaia Laboratory Director Report Date: December 13, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this meth gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analyst these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs b the above. Page 1 of 2

CITY_21MC100_002885787

NYC-WTC_000390336

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390336Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →