NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2089002
Rose Associates Inc. ELAP Lab Code: 11029 Analyte: FIBERS
200 Madison Ave. 5th Floor NIOSH and AIHA Lab Code: 100273 Date Received: 10/15/01
New York, NY 10016 NVLAP Lab Code: 101953 Date Analyzed: 10/16/01
Batch#: 011OA741
SUMMARY OF ANALYTICAL RESULTS
Site: 21 West Street, New York, NY
SAMPLE #
COLLECTED DESCRIPTION / LOCATION TIME(min) VOLUME(i) FIB/FIELD RESULTS(f/cc)
LAB #
001 Ambient/ Corridor/ 30th Floor/ Right Next to the 90 1385 6/100 0.002
12-October Entrance of Apartment 30C
A 7513
002 Ambient/ Inside! 30th Floor/ Inside Apartment 90 1385 7/100 0.002
12-October 30B/ At the North Section of the Room
A 7514
003 Ambient/ Corridor/ 25th Floor/ At the North 90 1385 6/100 0.002
12-October Section of the Corridor
A 7515
004 Ambient/ Corridor/ 25th Floor/ At the South 90 1385 8/100 0.003
12-October Section of the Corridor
A 7516
005 Ambient/ 20th Floor! At the North Section of the 90 1385 7/100 0.003
12-October Apartment 20B
A 7517
006 Ambient/ 20th Floor/ At the South Section of the 90 1385 8/100 0.003
12-October Corridor
A 7518
Sample Analysis by: <LOD = Less than limit of detection which Is 5.5 Fibers/ 100 Fields
Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles)
VOID2 = Overloaded
Method of Sample Preparation and Analysis:
All samples analyzed In accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994
Instrumentation: a t
Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). iiam aC I i
Laboratory Director
Report Date: October 16, 2001
JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other
limitations, this meth
gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising
out of JLC's analysi
these samples are limited In recovery to the cost of analyzing samples. JLC accepts no other liability and the client
agrees to seek no costs b
the above.
Page 1 of 5
NYC-WTC 000094657
OCR can misread numbers and units. Confirm readings against the page image before using them.