JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 03-2744 ELAP Lab Code: 11029 Analyte: FIBERS w York City D.E.P. NIOSH and AIHA Lab Code: 100273 Date Received: 3/30/2003 Junction Blvd. 7 NVLAP Lab Code: 101953 Date Analyzed: 3/30/2003 Flushing, NY 11373 Batch #: 0303A682 SUMMARY OF ANALYTICAL RESULTS - PCM Site: 114 Liberty Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION! LOCATION TIME(min) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB #

Final/ SE Bedroom/ Center of Room! 9th Floor 360 3650.4 4/100 0.001 019 29-March A 9466

020 Final! SW Bedroom/ Center of Room/ 9th Floor 360 3650.4 5/100 0.001 29-March A 9467

021 IWA/ Livingroom/ North Side/ 8th Floor 360 3650.4 5/100 0.001 29-March A 9468

2 IWA/ Diningroom/ East Side/ IWA 360 3650.4 6/100 0.001 9-March A 9469

023 IWA! Kitchen/ West Side/ 8th Floor 360 3650.4 6/100 0.001 29-March A 9470

024 IWA! 5E Bedroom/ Southeast/ 8th Floor 360 3650.4 8/100 0.001 29-March A 9471

Sample Analysis blr: <LOD = Less than limit of detection which is 5.5 Fibers! 100 Fields VOID1 = H.C.P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A° Counting Rules. issue 2, August 1994 Instrumentation: Gu1 fachhiwala La Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Laboratory Director Report Date: April 15, 2003 1* JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an Index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 50 of 67

NYC-WTC 000132031

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000132031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →