PCM final results, 12th Floor, 114 Liberty Street, Mar 2003

Machine-extracted title · confidence 42%

Final PCM fiber results from restrooms and areas on 12th Floor near Microtrap/IWA at 114 Liberty Street.

NYC-WTC_000331842–000331852
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 03-2744 New York City D.E.P. ELAP Lab Code: 11029 Analyte; FIBERS 17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Received: 3Z30/2003 rlushing, NY 11373 NVLAP Lab Code: 101953 Date Analyzed: 3/30/2003

SUMMARY OF ANALYTICAL RESULTS - PCM ososass?

Site: : 114 Liberty Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(mln) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB#

037 Final/ Sth Floor/ East Side of Dining Room 360 3650.4 8/100 0.001 29-March A 9484

038 Final/ Sth Floor/ Center of Kitchen 360 3650.4 7/100 0.001 29-March A 9485

039 Final/ 5th Floor/ SE Bedroom 360 3650.4 4/100 0.001 29-March A 9486

10 Final/ Sth Floor/ SW Bedroom 360 3650.4 4/100 0.001 _9-March A 9487

041 Final/ 4th Floor/ Center of Livingroom 360 3650.4 4/100 0.001 29-March A 9488

042 Final/ 4th Floor/ Center of Diningroom 360 3650.4 7/100 0.001 29-March A 9489

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2,y\ugu^ 1994 Instrumentation: Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Gulam Machhiwala Laboratory Director

Report Date: April 15, 2003 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 53 of 67

CITY_DEP_WORBY_CANNATA_SUBP_000036242

NYC-WTC_000331848

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000331848Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →