BMCC environmental testing, Dec 2001-Jan 2002

Machine-extracted title · confidence 41%

PSI testing results for Dec 26, 2001 and Jan 11, 2002; includes VOC and air quality findings.

NYC-WTC_000390175–000390176
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

January 14, 2002

Mr. Niles Miller Dormitory Authority State of New York One Penn Plaza, 52“* Floor New York, NY 10119

Subject: Environmental Testing (December 26“* and January 11") Borough of Manhattan Community College Trailers, North Building & South Building 199 Chambers Street, New York, NY PSI Project Number: 622-1A139

Dear Mr. Miller:

At the request of the Dormitory Authority State of New York, Professional Service Industries, Inc. (PSI) has been directed to perform periodic environmental testing at the Borough of Manhattan Community College’s, South Building, North Building and the temporary Trailers located at the West Side Highway adjacent to a staging area for WTC structural steel removal. This report covers the results of testing performed on December 26"', 2001 and January 11*, 2002.

Monitoring performed on 12/26/01 and 01/11/02 included testing for Airborne Asbestos, Airborne Silica, Respirable Dust, Total Dust and total Volatile Organic Compounds (VOC).

Testing results follow.

Monitoring Asbestos in Air PSI collected 12 representative air samples from alternate floors from within the North and South Buildings on December 26"’, 2001. Samples were collected and analyzed by Transmission Electron Microscopy in accordance with EPA 40 CFR Part 763 Final Rule (AHERA). AHERA regulations establish the post abatement air clearance criteria for asbestos abatement projects performed within schools (Grades K-12). The AHERA post asbestos abatement clearance criteria is defined as an airborne asbestos fiber concentration less than 70 structures per millimeter squared (<70 s/mm^). The samples collected are not intended to be post abatement clearance samples, and the results have been compared to the established AHERA criteria for the purposes of referencing an established regulatory limit.

Laboratory analysis detected no asbestos fibers present in the samples collected. Analytical results are shown below in Table 1.

CITY_21MC100_008854622

NYC-WTC_000390175

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390175Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →