NYC 9/11 Public Portal Document
Information
L '~ 74 Build Ott
~tt9 • • ro
December 17, 2001
Mr. Niles Miller
Dormitory Authority State of New York
One Penn Plaza, 52`d Floor
New York, NY 10119
Subject: Environmental Testing
Borough of Manhattan Community College
199 Chambers Street, New York, NY
PSI Project Number: 622-1.A139
Dear Mr. Miller:
At the request of the Dormitory Authority State of New York, Professional Service Industries, Inc
('PSI) has been directed to performed periodic environmental testing at the subject facility. The first
round of testing was performed on September 28 and September 29, 2001. Results of all air and
surface testing for asbestos, lead, silica, and dust at that time were below the established regulatory or
guideline levels for the selected analyte.
Due to accessibility issues PSI has been unable to return to the facility for subsequent testing uni
December 15 and December 17, 2001. Frequent periodic testing will be performed on the site u
•I further notice. PSI is working with $MCC facilities personnel to ensure Rill access to the site
Monitoring performed on 12/15 and 12117 includes testing for airborne asbestos, airborne silica,
respirable dust, selected airborne mera's and Total Volatile Organic Compounds
Preliminary testing results follow.
Monitoring Asbestos in Air
PSI collected 8 representative air samples from the Trailers at the West Side Highway location. In
addition, I sample was collected from within the Gymnasium (north building) and Theater I (scutb
building) as these areas were subject to use by emergency/rescue workers. Samples were collected
and analyzed by Transmission Electron Microscopy in accordance with EPA 40 CFR Part 763 Final
Rue (AI-RA) .JRA regulations establish the post abatement air clearance criteria for asbestos
abatement projects performed within schools (Grades K-12). The AHERA post asbestos abatement
clearance criteria is defined as an airborne asbestos fiber concentration less than 70 structures per
millimeter squared (<70 s/rnm2). The samples collected are not intended to be post abatement
clearance samples, and the results have been compared to the established AHERA criteria for the
purposes of referencing an established regulatory Iimit.
Laboratory analysis found no asbestos fibers present in any of the samples collected. Refer to Table I
for analytical results
Professional Sirviec'i' usti•s, Inc. • 8 8aet 37tH Street, 11th Floor • New York cirr. NY 10018 • prong 59.Q94 + Faa 212/989.0493
7'r', i.,'...-,t -,,•, 1^ _ >
NYC-WTC 000106380
OCR can misread numbers and units. Confirm readings against the page image before using them.