NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 46/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083378 365 South End Avenue, Building #300
Document / 22 pages

Fax cover sheet from LeFrank Organization, Sept 2001

Machine-extracted title · confidence 100%

Cover page for a fax transmission dated September 28, 2001, containing confidential environmental data.

NYC-WTC_000117772–000117793

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083378 365 South End Avenue, Building #300

Page image
Scanned page image, NYC-WTC_000117788
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Oct 05 01 11a17a ALC Environmental (212)279-9747 p.2

INOONPORAres The First Choice for Environmental Testing & Consulting

NYC DEP Mr. Krish Radhakrishnan, P.E. Director 59-17 Junction Boulevard, 8a' Floor Corona, NY 11368-5107 Via Facsimile

Subject: 1iaa1 Air Clearance Sampling: Gateway Plaza 355 Southend Avenue Building 200; Apartments-23F. 22F. 340.19H.17B.16F

Dear Mr. Radhakrishnan, P.E.

Please find enclosed the third party air monitoring report performed at selected locations of the above referenced location. Upon completion of the asbestos clean up procedures, a visual inspection was conducted in the work areas located in the in the specific apartments of the 200 building of the Gateway Playa. Since no visible asbestos containing material (acm) or debris was seen, final air clearance sampling was then conducted.

The air sampling and analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE II AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

The air samples were collected by Alvin B. Blake a licensed sampling technician (AH#01-03528) under the supervision of Americo Rodriguez Jr., a licensed project monitor (AH# 89-07160)

ATC Associates (ELAP #10879) analyzed the samples using the Transmission Electron Microscopy (TEM) Methodology. The t~sults indleatsd that the work areas achieved the acceptance criteria gf at or below <0.01 fibers per cubic centimeters set by the above regulations.

If you have any questions and/or comments please contact us directly at 212 279-1001.

a Sarett Environmental Inc.

Cc. Richard Lefrak, Charles Mehlman

115 West 30th Street a 11th Floor ® New York, New York 10001 a 212.279.1001 m 888.466.3620 % Fax: 212.279.6747 Ilona 0111cc: The Bellevue ® Suite 600 O 200 S. Broad Street o Philadelphia, PA 19102 0 215.732.9499 ® 888.789.8378 ® Fax: 215.732.9559 www.ALCEnvtronmentaI.com

NYC-WTC 000117788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →