Air monitoring report, 345 South End Avenue, Mar 2002

Machine-extracted title · confidence 95%

Air monitoring report for 345 South End Avenue buildings conducted in March 2002 showing TEM results.

NYC-WTC_000121076–000121137

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: Parking Garage

Page image
Scanned page image, NYC-WTC_000121076
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIth ENVIRONMENTAL INCORPORA TED The First Choice for Environmental Testing & Consulting

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280

Subject: Random Air Sampling-Ambient Air Monitoring: Gateway Plaza Buildings Sampling Date(s): March 7, 8, 11, 12, 13, 14, 15, 18, 19, 20, 21, 22, 25, 26, 27

Gentlemen:

Please find enclosed the air monitoring report performed at the above referenced address in the 100, 200, 300, 400, 500 and 600 buildings. Air sampling was conducted via Transmission Electron Microscopy (TEM) analysis at the request of the owner.

ATC Associates (ELAP #10879) analyzed the samples using the Transmission Electron Microscopy (TEM) Methodology. The results indicated that the areas achieved the acceptance criteria below <70 structures per mm2 set by the federal regulations. (Please See Attached TEM Report) According to the EPA, "In evaluating data from the World Trade Center and the surrounding areas. EPA is using a protective standard under AHERA, the Asbestos Hazard Emergency Response Act, to evaluate the riskfrom asbestos in the outdoor and indoor air. This is a very stringent standard that is used to determine whether children may re-enter a school building after asbestos has been removed or abated. Iris based on assumptions of long-term exposure. EPA has chosen to use this standard, because it is the most stringent and protective, even though iris unlikely that the public will be exposed to asbestosfrom the World Trade Center sitefor extended periods of time.

To determine asbestos levels, airfilters are collectedfrom monitoring equipment through which air in the school building has passed and viewed through a microscope. The number ofstructures — material that has asbestosfibers on or in it — is then counted. The measurements must be 70 orfewer structures per square millimeter before children are allowed inside.

There is also afederal standardfor asbestos exposure under OSHA, the Occupational Safety and Health Act, which is used to protect workers on-the-job. The standard is .1fiber per cubic centimeter averaged over an eight-hour day. To be as protective as possible, EPA is using the school re-entry standard in tests around the World Trade Center.

Levels above 70 structures per square millimeter do NOT imply an immediate health threat. Asbestos exposure becomes a health concern when high concentrations of asbestosfibers are inhaled over a long period. Illness is very unlikely to resultfrom a single, high-level exposure, orfrom a short period of exposure to lower levels." The air samples were collected by Michael Kamtn<as (License #AH 97-17055), Nyron Williams (License #AH 98-10213 nd Robert Nelson (License #AH 97-11694) NY State Department of Labor Project Monitors. ( ti -

Michael Kamm ALC Environm tal Incorporated

115 West 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax: 212.279.6747 (Ofic The Bellevue • Suite 600 • 200 S. Broad Street • Philadelphia, PA 19102 • 215.7329499 • 888.789.8378 • Fax: 215.732.9559

tv.ALCEnviron inc nut!.corn

NYC-WTC 000121076

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121076Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →