NYC 9/11 Public Portal Document
~ IZ ,~lov
January 14, 2002
Mr. Niles Miller
Dbrn itory Authority State of New York
One Penn Plaza, 52d Floor
New York, NY 10119
Subject: Environmental Testing (December 26th and January 11t1)
Borough of Manhattan Community College
Trailers, North Building & South Building
199 Chambers Street, New York, NY
PSI Project Number. 622-1A139
Dear Mr. Miller:
At the request of the Dormitory Authority State of New York, Professional Service Industries,
Inc. (PSI) has been directed to perform periodic environmental testing at the Borough of
Manhattan Community College's, South Building, North Building and the temporary Trailers located
at the West Side Highway adjacent to a staging area for WTC structural steel removal. This report
covers the results of testing performed on December 26th, 2001 and January 11th, 2002.
Monitoring performed on 12/26/01 and 01/11/02 included testing for Airborne Asbestos,
Airborne Silica, Respirable Dust, Total Dust and total Volatile Organic Compounds (VOC).
Testing results follow.
Monitoring Asbestos in Air
PSI collected 12 representative air samples from alternate floors from within the North and
South Buildings on December 26th, 2001. Samples were collected and analyzed by Transmission
Electron Microscopy in accordance with EPA 40 CFR Part 763 Final Rule (AHERA). AHERA
regulations establish the post abatement air clearance criteria for asbestos abatement projects
performed within schools (Grades K-12). The AHERA post asbestos abatement clearance
criteria is defined as an airborne asbestos fiber concentration less than 70 structures per
millimeter squared (<70 s/mm2). The samples collected are not intended to be post abatement
clearance samples, and the results have been compared to the established AHERA criteria for
the purposes of referencing an established regulatory limit.
Laboratory analysis detected no asbestos fibers present in the samples collected. Analytical
results are shown below in Table 1.