Subject: Environmental Testing (January 31'` and February 1, 2002)
Borough of Manhattan Community College
Trailers, North Building & South Building
199 Chambers Street, New York, NY
PSI Project Number. 622-1A139
Dear Mr. Miller:
At the request of the Dormitory Authority State of New York, Professional Service Industries,
Inc. (PSI) has been directed to perform periodic environmental testing at the Borough of
Manhattan Community College's, South Building, North Building and the temporary Trailers located
at the West Side Highway adjacent to a staging area for WTC structural steel removal. This report
covers the results of testing performed on January 31th and February 1, 2002.
Monitoring performed on 1/31/02 and 02/01/02 included testing for Airborne Asbestos,
Asbestos in Dust, Lead Surface Sampling, Airborne Silica, Respirable Dust, Total Dust and total
Volatile Organic Compounds (VOC).
At the time samples were collected, Trailer windows were closed and }{EPA air filtration units
were operating.
Based on the methodologies described in this report, this assessment revealed that, at the time of
testing, measured parameters were within recommended guidelines.
Testing results follow.
Monitoring Asbestos in Air
PSI collected 16 representative air samples from alternate floors from within the North and
South Buildings and 8 representative air samples from each of eight of the Trailers on February
2 , 2001. Samples were collected and analyzed by Transmission Electron Microscopy in
accordance with Environmental Protection Agency (EPA) 40 CFR Part 763 Final Rule -
Asbestos Hazard Emergency Response Act (AHERA). AHERA regulations establish the post
abatement air clearance criteria for asbestos abatement projects performed within schools
(Grades K-12). The AHERA post asbestos abatement clearance criteria is defined as an airborne
asbestos fiber concentration less than 70 structures per millimeter squared (<70 slmm2). The
samples collected are not intended to be post abatement clearance samples, and the results have