Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
KAMCONSUUANTS
35-40 36th Street
Long Island City
NewYork,11106
Tel:(718)729-W
Fax: 718)729-1875
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 14-22 Reade Street, Manhattan
PROJECT#:
Client Sample ID# 25B 26A 26B 27A 27B
Lab Sample 1Df» 010905B-215 010905B-216 010905B-217 010905B-218 010905B-219
Sample Location Roof "A" Root "A" Roof"A" Roof "A" Roof"A"
Homogeneity Yes Yes Yes Yes Yes
Sample Description Base Flashing Base Flashing Base Flashing Base Flashing Base Flashing
2nd Laver 1st La\ei 2nd Laver Ist Laver 2nd Laver
Color Blk Blk Blk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment Acid Digestion Acid Digestion ■Acid Digestion Acid Digestion Acid Digestion
& Ashing & Ashing & Ashing & Ashing & Ashing
Asbestos Present-
(Type & Percent) 1 23%CHR 2 0%CHR 1 42%CHR 19%CHR 1 5%CHR
Total Percent
Asbestos: 1.23% 2% 1.42% 1.9% 1.5%
Other Fibr. Mat
(Type & Percent)- 0% 0% 0% 0% 0%
Non Fibr. Mat.
(Percent): 98.77% 98% 98 58% 98 1% 98.5%
Date Received- 9/5/01
Date of Analysis 9/6/01
Date of Report; 9/7/01
Analyst: VV\ . l /l /XTAil-ckt Lab Mana;
M. Ulanecki David Chen
* Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested
♦ The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
NYS-DOH ELAP #11273 NIST-NYLAP # 102047 AIHA#: 100269
12
NYC-WTC_000386157
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000386157Source: NYC Law Department, mirrored locally