Bulk sample analysis report, 14-22 DCAS

Machine-extracted title · confidence 25%

DCAS bulk sampling notes for 14-22 building project files.

NYC-WTC_000386152
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUXNTS 35-40 36th Street Long Island City NewYork,11106 Tel: (716 729-1997 Fax: (718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample IDs 8B 9A 9B lOA I OB Lab Sample ID’f 010905B-175 010905B-176 010905B-177 0'109058-178 010905B-179 Sample Location Bulkhead #2 Bulkhead ?2 Bulkhead */2 Machine Room #1 Machine Room ?1

Homogeneity Yes Yes Yes Yes Yes Sample Description Base Flashing Base Flashing Base Flashing Roof Membrane Roof Membrane 2nd Laver 1st Laver 2nd La;.er 1st Laver 2nd Laver

Color Blk Blk BIk Blk Blue Texture Mixed Fibrous Mixed Fibrous Non Fibrous Sample Treatment Acid Digestion None Acid Digestion None Acid Digestion & Ashing & Ashing & Ashing Asbestos Present (Type & Percent) 11 86%CHR ND 16 72%CHR ND ND Total Percent Asbestos; 11.860% 0% 16.720% 0% 0% Other Fibr. Mat. (Type & Percent) 0% 90%FBGL 0% 95%FBGL 0% Non Fibr Mat. (Percent): 88 140% 10% 83 280% 5% 100% Date Received 9/5/01 Date of Analysis 9/6/01 Date of Report 9/7/01

Analyst: AYIJ- Lab Manager: 1 M. Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing ♦ Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NfST-NVLAP »102047 AIHA ff: 100269

4

NYC-WTC_000386152

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386152Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →