NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 26 pages

Bulk sample analysis, 14-22 [name], Manhattan

Machine-extracted title · confidence 42%

Bulk sample analysis report for NYC-DCAS, listing Lab Sample IDs and sample locations.

NYC-WTC_000268233–000268258
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUDANTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1997 Fax: (718)729-1876 w

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#; Client Sample ID# : 8B 9A 9E lOA lOB Lab Sample IDlf : 010905B-175 010905B-176 010905B-177 0109058-178 010905B-179 Sample Location: Bulkhead #2 Bulkhead »2 Bclkiiead ^2 Machine Room #1 Machine Room

Homiogeneity: Yes Yes Yes Yes Yes

Sample Description Base Flashing Base Flashing Base Flashing Roof Membrane Roof Membrane 2nd Layer 1 st Layer 2nd Laver I SI Layer 2nd Layer

Color: Blk Blk Blk Blk Blue

Texture: Mixed Fibrous Mixed Fibrous Non Fibrous

Sample Treatment; Acid Digestion None Acid Digestion None Acid Digestion & Ashing & Ashing & Ashing Asbestos Present: (Type & Percent) 11.86%CHR ND 16.72%CHR ND ND Total Percent Asbestos: 11.860% 0% 16.720% 0% 0%

Other Fibr. Mat. (Type & Percent); 0% 90%FBGL O’/'o 95%FBGL 0% Non Fibr. Mat. (Percent); 88.140% 10% 83,280% 5% 100% Date Received: 9/5/01 Date of Analysis; 9/6/01 Date of Report; 9/7/01

Analyst: Lab Manager; 1 M. Ulanecki Dav'idChen^ * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial » 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NELAP # 102047 AIHA #: 100269

4

CITY_21MC100_0 06262465

NYC-WTC_000268236

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268236Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →