KAM CONSULTANTS 35-4(136th Street Long Island City New York, 11106 Tel: (718)729-1997 Fax: (718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT; NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# : IOC llA ilB lie 12A Lab Sample ID# : O1O9O5B-18O 0I0905B-181 0I0905B-I82 010905B-183 010905B-I84 Sample Location: Machine Room # 1 Machine Room #1 Machine Room #1 Machine Room # 1 Machine Room #I

Homogeneity: Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Roof Membrane 3rd Layer 1 st Layer 2nd Layer 3rd Layer 1 st Layer

Color: Blk Blue Blue Blue Blue Texture: Mixed Mixed Non Fibrous Mixed Fibrous Sample Treatment: Acid Digestion Acid Digestion Acid Digestion Acid Digestion None & Ashing & Ashing & Ashing & Ashing Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat, (Type & Percent): 40%FBGL 95%FBGL 0% 30%FBGL 95%FBGL Non Fibr. Mat. (Percent): 60% 5% 100% 70% 5% Date Received: 9/5/01 Date of Analysis: 9/6/01

AJ2 Date of Report: 9/7/01

Analyst; Lab Manager: V- M. Ulanecki David Chen ♦ Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 6O0/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP 11273 NIST-NELAP » 102047 AIHA »: 100269

5

CITY_21MC100_0 06262466

NYC-WTC_000268237

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268237Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →