KAMCONSUUANTS 35-40 36th Street Long Island City New York, 11106 Tel: (718)729-1997 Fax: (718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# : 37B 38A 38B 39a 39B Lab Sample ID//: 010905B-245 010905B-246 O10905B-247 0I0905B-248 010905B-249 Sample Location: Roof"C" Roof'C" Roof'C Roof'C" Roof'C"

Homogeneity: Yes Yes Yes Yes Yes

Sample Description Base Flashing Base Flashing E;a;;e Flashing Base Flashing Base Flashing 2nd Layer 1st Layer 2nd Layer I st Layer 2nd Layer

Color: Blk Blk Blk Blk Blk

Texture: Mixed Mixed Mixed Mixed Mixed

Sample Treatment: Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present: (Type & Percent) 1.86%CHR L98%CHR 2.49%CHR 2,71%CHR 3.57%CHR Total Percent Asbestos: 1.86% 1,98% 2.49% 2.71% 3.57%

Other Fibr. Mat. (Type & Percent): 0% 0% 0% 0% 0% Non Fibr. Mat. (Percent): 98.14% 98.02% 97.51% 97.29% 96.43% Date Received: 9/5/01 Date of Analysis: 9/6/01 Date of Report: 9/7/01

Analyst: YV> , (VViL cjs, i Lab Manager: M. Ulanecki David Chen ♦ Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/f44-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Liglit Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials, Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. N¥S-DOff ELAP 1/273 MST-NELAP » /020^17 A/HA ff: 100269

18

CITY_21MC100_0 06262479

NYC-WTC_000268250

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268250Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →